CodeChronicle

OBC 2006 Division B

9.29.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.29. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.29. — Pro

9.29. — Interior Wall and Ceiling Finishes

Content not available for this version.

9.29.1. — General

Content not available for this version.

9.29.1.1. — Fire Protection and Sound Control

(1) A wall or ceiling finish shall also conform to the appropriate requirements in Sections 9.10. and 9.11. in addition to the requirements in this Section.

Text · e-Laws consolidated snapshot

9.29.2. — Waterproof Wall Finish

Content not available for this version.

9.29.2.1. — Where Required

(1) Waterproof finish shall be provided to a height of not less than,

(a) 1 800 mm above the floor in shower stalls,

(b) 1 200 mm above the rims of bathtubs equipped with showers, and

(c) 400 mm above the rims of bathtubs not equipped with showers.

Text · e-Laws consolidated snapshot

9.29.2.2. — Materials

(1) Waterproof finish shall consist of ceramic, plastic or metal tile, sheet vinyl, tempered hardboard, laminated thermosetting decorative sheets or linoleum.

Text · e-Laws consolidated snapshot

9.29.3. — Wood Furring

Content not available for this version.

9.29.3.1. — Size and Spacing of Furring

(1) Wood furring for the attachment of wall and ceiling finishes shall conform to Table 9.29.3.1.

Text · e-Laws consolidated snapshot

Table 9.29.3.1. Size and Spacing of Furring Forming Part of Sentence 9.29.3.1.(1)

Column 1

Column 2

Column 3

Column 4

Maximum Spacing of Furring, mm

Minimum Size of Furring, mm

Maximum Spacing of Furring Supports

Continuous Supports

400 mm (o.c.)

600 mm (o.c.)

300

19 × 38

19 × 38

19 × 64

400

19 × 38

19 × 38

19 × 64

600

19 × 38

19 × 64

19 × 89

9.29.3.2. — Fastening

(1) Furring shall be fastened to the framing or to wood blocks with not less than 51 mm nails.

Text · e-Laws consolidated snapshot

9.29.4. — Plastering

Content not available for this version.

9.29.4.1. — Application

(1) Application of plaster wall and ceiling finishes including installation of metal or gypsum lath, shall conform to CSA A82.30-M, “Interior Furring, Lathing and Gypsum Plastering”.

Text · e-Laws consolidated snapshot

9.29.5. — Gypsum Board Finish (Taped Joints)

Content not available for this version.

9.29.5.1. — Application

(1) The requirements for application of gypsum board in this Subsection apply to the single layer application of gypsum board to wood furring or framing using nails or screws.

(2) Gypsum board applications not described in this Subsection shall conform to CSA A82.31-M, “Gypsum Board Application”.

Text · e-Laws consolidated snapshot

9.29.5.2. — Materials

(1) Gypsum products shall conform to,

(a) CAN/CSA-A82.27-M, “Gypsum Board”,

(b) ASTM C36 / C36M, “Gypsum Wallboard”,

(c) ASTM C37 / C37M, “Gypsum Lath”,

(d) ASTM C442 / C442M, “Gypsum Backing Board, and Gypsum Coreboard, and Gypsum Shaftliner Board”,

(e) ASTM C558 / C588M, “Gypsum Base for Veneer Plaster”,

(f) ASTM C630 / C630M, “Water-Resistant Gypsum Backing Board”,

(g) ASTM C931 / C931M, “Exterior Gypsum Soffit Board”,

(h) ASTM C960 / C960M, “Predecorated Gypsum Board”,

(i) ASTM C1178 / C1178M, “Glass Mat Water-Resistant Gypsum Backing Panel”,

(j) ASTM C1395 / C1395M, “Gypsum Ceiling Board”, or

(k) ASTM C1396 / C1396M, “Gypsum Board”.

Text · e-Laws consolidated snapshot

9.29.5.3. — Maximum Spacing of Supports

(1) Maximum spacing of supports for gypsum board applied as a single layer shall conform to Table 9.29.5.3.

Text · e-Laws consolidated snapshot

Table 9.29.5.3. Spacing of Supports for Gypsum Board Forming Part of Sentence 9.29.5.3.(1)

Column 1

Column 2

Column 3

Column 4

Column 5

Thickness, mm

Orientation of Board to Framing

Maximum Spacing of Supports, mm o.c.

Walls

Ceilings

Painted Finish

Water-Based Texture Finish

Gypsum board conforming to Clauses 9.29.5.2.(1)(a)v1v2 to (i) and (k)

9.5

parallel

perpendicular

400

400

12.7

parallel

600

400

perpendicular

600

600

400

15.9

parallel

600

400

perpendicular

600

600

600

Gypsum board conforming to Clause 9.29.5.2.(1)(j)v1v2

12.7

parallel

600

400

perpendicular

600

600

600

9.29.5.4. — Support of Insulation

(1) Gypsum board supporting insulation shall be at least 12.7 mm thick.

Text · e-Laws consolidated snapshot

9.29.5.5. — Length of Fasteners

(1) The length of fasteners for gypsum board shall conform to Table 9.29.5.5., except that lesser depths of penetration are permitted for assemblies required to have a fire-resistance rating provided it can be shown, on the basis of fire tests, that such depths are adequate for the required rating.

Text · e-Laws consolidated snapshot

Table 9.29.5.5. Fastener Penetration into Wood Supports Forming Part of Sentence 9.29.5.5.(1)

Column 1

Column 2

Column 3

Column 4

Column 5

Required Fire-Resistance Rating of Assembly

Minimum Penetration, mm

Walls

Ceilings

Nails

Screws

Nails

Screws

Not required

20

15

20

15

45 min

20

20

30

30

1 h

20

20

45

45

1.5 h

20

20

60

60

9.29.5.6. — Nails

(1) Nails for fastening gypsum board to wood supports shall conform to CSA B111, “Wire Nails, Spikes and Staples”.

Text · e-Laws consolidated snapshot

9.29.5.7. — Screws

(1) Screws for fastening gypsum board to wood supports shall conform to ASTM C1002, “Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs”.

Text · e-Laws consolidated snapshot

9.29.5.8. — Spacing of Nails

(1) For single-layer application on ceilings, nails shall be spaced,

(a) not more than 180 mm o.c. on ceiling supports, or

(b) every 300 mm o.c. along ceiling supports, in pairs about 50 mm apart.

(2) Where the ceiling sheets are supported by the wall sheets around the perimeter of the ceiling, this support may be considered as equivalent to nailing at this location.

(3) Except as required by Sentence (4), for single-layer application on walls, nails shall be spaced,

(a) not more than 200 mm o.c. on vertical wall supports, or

(b) every 300 mm o.c. along vertical wall supports, in pairs about 50 mm apart.

(4) For single-layer application on walls, where gypsum board is required to provide bracing, lateral support or fire protection, nails shall be spaced not more than 200 mm o.c. on,

(a) vertical wall supports, and

(b) top and bottom plates.

(5) The uppermost nails on vertical wall supports shall be not more than 200 mm below the ceiling.

(6) Nails shall be located not less than 10 mm from the side or edge of the board.

(7) Nails shall be driven so that the heads do not puncture the paper.

Text · e-Laws consolidated snapshot

9.29.5.9. — Spacing of Screws

(1) For single-layer application on a ceiling, screws shall be spaced not more than 300 mm o.c. on ceiling supports.

(2) Where the ceiling sheets are supported by the wall sheets around the perimeter of the ceiling, this support may be considered as equivalent to screwing at this location.

(3) Except as required by Sentence (4), for single-layer application on walls, screws shall be spaced,

(a) not more than 300 mm o.c. on vertical wall supports where the supports are more than 400 mm o.c., or

(b) not more than 400 mm o.c. on vertical wall supports where the supports are not more than 400 mm o.c.

(4) Except as required by Sentence (5), for single-layer application on walls, where gypsum board is required to provide bracing, lateral support or fire protection, screws shall be spaced not more than 300 mm o.c. on,

(a) vertical wall supports, and

(b) top and bottom plates.

(5) Where a fire-resistance rating is determined based on Supplementary Standard SB-3, Sentence (4) need not apply for the purpose of fire protection.

(6) Screws shall be located not less than 10 mm from the side or edge of the board.

(7) Screws shall be driven so that the heads do not puncture the paper.

Text · e-Laws consolidated snapshot

9.29.5.10. — Low Temperature Conditions

(1) In cold weather, heat shall be provided to maintain a temperature of not below 10°C for 48 h prior to taping and finishing and maintained for not less than 48 h after that.

Text · e-Laws consolidated snapshot

9.29.6. — Plywood Finish

Content not available for this version.

9.29.6.1. — Thickness

(1) Except as provided in Sentences (2) and (3), the minimum thickness of plywood interior finish shall conform to Table 9.29.6.1.

(2) A manufacturing tolerance of – 0.4 mm may be applied to the thicknesses listed in Table 9.29.6.1.

(3) No minimum thickness is required where plywood is applied over continuous backing.

Editor's note

In the notes to Table-9.29.6.1., the footnote reference numbers are presented inline with a separating space; the e-Laws consolidation renders them as superscript abutting the text. The footnote text is identical.

Text · e-Laws consolidated snapshot

Table 9.29.6.1. Thickness of Plywood Interior Finish Forming Part of Articles 9.29.6.1., 9.29.6.2. and 9.29.9.2.

Column 1

Column 2

Column 3

Maximum Spacing of Supports, mm o.c.

Minimum Thickness, mm(1), on Supports with no Horizontal Blocking

Minimum Thickness, mm(1), on Supports with Blocking at Vertical Intervals not Exceeding 1.2 m

400

4.7

4.0

600

8.0

4.7

Notes to Table 9.29.6.1.

(1)Thickness limits shall apply to the net effective thickness (NET) of grooved, striated, textured and/or embossed panels and to the actual thickness of flat panels.

9.29.6.2. — Grooved Plywood

(1) Except as permitted in Sentence (2), where plywood for interior finish is grooved, the grooves shall not extend through the face ply and into the plies below the face ply unless the groove is supported by framing or furring.

(2) If the grain of the face ply is at right angles to the supporting members, the groove is permitted to extend into the plies below the face ply provided the thickness of the plywood exceeds the value shown in Table 9.29.6.1. by an amount equal to not less than the depth of penetration of the grooves into the plies below the face ply.

Text · e-Laws consolidated snapshot

9.29.6.3. — Nails and Staples

(1) Nails for attaching plywood finishes shall not be less than 38 mm casing or finishing nails spaced not more than 150 mm o.c. along edge supports and 300 mm o.c. along intermediate supports, except that staples providing equivalent lateral resistance may also be used.

Text · e-Laws consolidated snapshot

9.29.6.4. — Edge Support

(1) All plywood edges shall be supported by furring, blocking or framing.

Text · e-Laws consolidated snapshot

9.29.7. — Hardboard Finish

Content not available for this version.

9.29.7.1. — Material Standard

(1) Hardboard shall conform to CAN/CGSB-11.3-M, “Hardboard”.

Text · e-Laws consolidated snapshot

9.29.7.2. — Thickness

(1) Hardboard shall be not less than,

(a) 3 mm thick where applied over continuous back-up,

(b) 6 mm thick where applied to supports spaced not more than 400 mm o.c., and

(c) 9 mm thick where applied to supports spaced not more than 600 mm o.c.

Text · e-Laws consolidated snapshot

9.29.7.3. — Nails

(1) Nails for fastening hardboard shall be casing or finishing nails not less than 38 mm long, spaced not more than 150 mm o.c. along edge supports and 300 mm o.c. along intermediate supports.

Text · e-Laws consolidated snapshot

9.29.7.4. — Edge Support

(1) All hardboard edges shall be supported by furring, blocking or framing where the back-up is not continuous.

Text · e-Laws consolidated snapshot

9.29.8. — Insulating Fibreboard Finish

Content not available for this version.

9.29.8.1. — Material Standard

(1) Insulating fibreboard shall conform to CAN/ULC-S706, “Wood Fibre Thermal Insulation for Buildings”.

Text · e-Laws consolidated snapshot

9.29.8.2. — Thickness

(1) Insulating fibreboard sheets shall be not less than 11.1 mm thick on supports not more than 400 mm o.c.

(2) Insulating fibreboard tile shall be not less than 12.7 mm thick on supports spaced not more than 400 mm o.c.

Text · e-Laws consolidated snapshot

9.29.8.3. — Nails

(1) Nails for fastening fibreboard sheets shall be not less than 2.6 mm shank diameter casing or finishing nails of sufficient length to penetrate not less than 20 mm into the supports.

(2) Nails shall be spaced not more than 100 mm o.c. along edge supports and 200 mm o.c. along intermediate supports.

Text · e-Laws consolidated snapshot

9.29.8.4. — Edge Support

(1) All fibreboard edges shall be supported by blocking, furring or framing.

Text · e-Laws consolidated snapshot

9.29.9. — Particleboard, OSB or Waferboard Finish

Content not available for this version.

9.29.9.1. — Material Standard

(1) Particleboard finish shall conform to ANSI A208.1, “Particleboard, Mat-Formed Wood”.

(2) OSB or waferboard finish shall conform to,

(a) CAN/CSA-O.325, “Construction Sheathing”, or

(b) CSA O437.0, “OSB and Waferboard”.

Text · e-Laws consolidated snapshot

9.29.9.2. — Minimum Thickness

(1) Except as provided in Sentences (2) and (3), the minimum thickness of O-2 grade OSB used as an interior finish shall conform to that shown for plywood in Table 9.29.6.1.

(2) Thickness listed in Table 9.29.6.1. shall permit a manufacturing tolerance of – 0.4 mm.

(3) No minimum thickness is required where O-2 grade OSB is applied over continuous backing.

(4) OSB conforming to O-1 grade, waferboard conforming to R-1 grade and particleboard shall be,

(a) not less than 6.35 mm thick on supports not more than 400 mm o.c.,

(b) not less than 9.5 mm thick on supports not more than 600 mm o.c., and

(c) not less than 6.35 mm thick on supports not more than 600 mm o.c. in walls where blocking is provided at midwall height.

(5) OSB conforming to CAN/CSA-O325.0, “Construction Sheathing”, shall meet the minimum panel mark of,

(a) W16, on supports not more than 400 mm o.c.,

(b) W24, on supports not more than 600 mm o.c., and

(c) W16, on supports not more than 600 mm o.c. where blocking is provided at midwall height.

Text · e-Laws consolidated snapshot

9.29.9.3. — Nails

(1) Nails for fastening particleboard, OSB or waferboard shall be not less than 38 mm casing or finishing nails spaced not more than 150 mm o.c. along edge supports and 300 mm o.c. along intermediate supports.

Text · e-Laws consolidated snapshot

9.29.9.4. — Edge Support

(1) All particleboard, OSB or waferboard edges shall be supported by furring, blocking or framing.

Text · e-Laws consolidated snapshot

9.29.10. — Wall Tile Finish

Content not available for this version.

9.29.10.1. — Tile Application

(1) Ceramic tile shall be set in a mortar base or applied with an adhesive.

(2) Plastic tile shall be applied with an adhesive.

Text · e-Laws consolidated snapshot

9.29.10.2. — Mortar Base

(1) When ceramic tile is applied to a mortar base the cementitious material shall consist of 1 part Portland cement to not more than one-quarter part lime by volume.

(2) The cementitious material described in Sentence (1) shall be mixed with no fewer than 3 nor more than 5 parts of aggregate per part of cementitious material by volume.

(3) Mortar shall be applied over metal lath or masonry.

(4) Ceramic tile applied to a mortar base shall be thoroughly soaked and pressed into place forcing the mortar into the joints while the tile is wet.

Text · e-Laws consolidated snapshot

9.29.10.3. — Adhesives

(1) Adhesives to attach ceramic and plastic tile shall be applied to the finish coat or brown coat of plaster that has been steel-trowelled to an even surface or to gypsum board or to masonry provided the masonry has an even surface.

Text · e-Laws consolidated snapshot

9.29.10.4. — Moisture Resistant Backing

(1) Ceramic and plastic tile installed on walls around bathtubs or showers shall be applied over moisture resistant backing.

Text · e-Laws consolidated snapshot

9.29.10.5. — Joints between Tiles and Bathtub

(1) The joints between wall tiles and a bathtub or shower shall be suitably caulked with material conforming to CAN/CGSB-19.22-M, “Mildew Resistant Sealing Compound for Tubs and Tile”.

Text · e-Laws consolidated snapshot