9.29.3. — Wood Furring

Content not available for this version.

9.29.3.1. — Size and Spacing of Furring

(1) Wood furring for the attachment of wall and ceiling finishes shall conform to Table 9.29.3.1.

Text · e-Laws consolidated snapshot

Table 9.29.3.1. Size and Spacing of Furring Forming Part of Sentence 9.29.3.1.(1)

Column 1

Column 2

Column 3

Column 4

Maximum Spacing of Furring, mm

Minimum Size of Furring, mm

Maximum Spacing of Furring Supports

Continuous Supports

400 mm (o.c.)

600 mm (o.c.)

300

19 × 38

19 × 38

19 × 64

400

19 × 38

19 × 38

19 × 64

600

19 × 38

19 × 64

19 × 89

9.29.3.2. — Fastening

(1) Furring shall be fastened to the framing or to wood blocks with not less than 51 mm nails.