9.29.6.1. — Thickness

(1) Except as provided in Sentences (2) and (3), the minimum thickness of plywood interior finish shall conform to Table 9.29.6.1.

(2) A manufacturing tolerance of – 0.4 mm may be applied to the thicknesses listed in Table 9.29.6.1.

(3) No minimum thickness is required where plywood is applied over continuous backing.

Editor's note

In the notes to Table-9.29.6.1., the footnote reference numbers are presented inline with a separating space; the e-Laws consolidation renders them as superscript abutting the text. The footnote text is identical.

Text · e-Laws consolidated snapshot

Table 9.29.6.1. Thickness of Plywood Interior Finish Forming Part of Articles 9.29.6.1., 9.29.6.2. and 9.29.9.2.

Column 1

Column 2

Column 3

Maximum Spacing of Supports, mm o.c.

Minimum Thickness, mm(1), on Supports with no Horizontal Blocking

Minimum Thickness, mm(1), on Supports with Blocking at Vertical Intervals not Exceeding 1.2 m

400

4.7

4.0

600

8.0

4.7

Notes to Table 9.29.6.1.

(1)Thickness limits shall apply to the net effective thickness (NET) of grooved, striated, textured and/or embossed panels and to the actual thickness of flat panels.