CodeChronicle

OBC 2006 Division B

9.24.1.5.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.24.1.5. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.24.1.5. — Pro

9.24.1.5. — Cladding, Sheathing and Interior Finish Required

(1) Cladding or sheathing, and interior finish shall be installed on steel stud framing and shall be fastened with screws,

(a) spaced at the appropriate spacing described in Section 9.29., and

(b) penetrating not less than 10 mm through the metal.

Text · e-Laws consolidated snapshot