9.30. — Flooring

Content not available for this version.

9.30.1. — General

Content not available for this version.

9.30.1.1. — Required Finish Flooring

(1) Finished flooring shall be provided in all residential occupancies.

Text · e-Laws consolidated snapshot

9.30.1.2. — Water Resistance

(1) Finished flooring in bathrooms, kitchens, public entrance halls, laundry and general storage areas shall consist of resilient flooring, felted-synthetic-fibre floor coverings, concrete, terrazzo, ceramic tile, mastic or other types of flooring providing similar degrees of water resistance.

Text · e-Laws consolidated snapshot

9.30.1.3. — Sleepers

(1) Wood sleepers supporting finished flooring over a concrete base supported on the ground shall be not less than 19 mm by 38 mm and shall be treated with a wood preservative.

Text · e-Laws consolidated snapshot

9.30.1.4. — Finish Quality

(1) Finished flooring shall have a surface that is smooth, even and free from roughness or open defects.

Text · e-Laws consolidated snapshot

9.30.2. — Panel-Type Underlay

Content not available for this version.

9.30.2.1. — Required Underlay

(1) A panel-type underlay shall be provided under resilient flooring, parquet flooring, ceramic tile, felted-synthetic-fibre floor coverings or carpeting laid over lumber subflooring.

(2) A panel-type underlay shall be provided under resilient flooring, parquet flooring, felted-synthetic-fibre floor coverings or carpeting on panel-type subflooring whose edges are unsupported.

(3) Panel-type underlay shall be provided under ceramic tile applied with adhesive.

(4) Panel-type underlay shall be provided under resilient flooring on waferboard or strandboard subflooring.

Text · e-Laws consolidated snapshot

9.30.2.2. — Materials and Thickness

(1) Panel-type underlay shall be not less than 6 mm thick and shall conform to,

(a) ANSI A208.1, “Particleboard, Mat-Formed Wood”,

(b) CAN/CGSB-11.3-M, “Hardboard”,

(c) CSA O115-M, “Hardwood and Decorative Plywood”,

(d) CSA O121-M, “Douglas Fir Plywood”,

(e) CSA O151, “Canadian Softwood Plywood”,

(f) CSA O153-M, “Poplar Plywood”, or

(g) CSA O437.0, “OSB and Waferboard”.

Text · e-Laws consolidated snapshot

9.30.2.3. — Fastening

(1) Panel-type underlay shall be fastened to the subfloor with staples, annular grooved flooring nails or spiral nails, spaced not more than 150 mm o.c. along the edges and 200 mm o.c. both ways at other locations.

(2) Nails for panel-type underlay shall be not less than 19 mm long for 6 mm thick underlay and 22 mm long for 7.9 mm thick underlay.

(3) Staples for panel-type underlay shall,

(a) have not less than a 1.2 mm shank diameter or thickness with a 4.7 mm crown, and

(b) be not less than,

(i) 22 mm long for 6 mm underlay, and

(ii) 28 mm long for 7.9 mm and 9.5 mm underlay.

Text · e-Laws consolidated snapshot

9.30.2.4. — Joints Offset

(1) Where panel-type underlay is required to be installed over plywood, or OSB or waferboard, the joints in the underlay shall be offset at least 200 mm from the joints in the underlying subfloor.

Text · e-Laws consolidated snapshot

9.30.2.5. — Surface Defects

(1) Underlay beneath resilient or ceramic floors applied with an adhesive shall have all holes or open defects on the surface patched so that the defects will not be transmitted to the finished surface.

Text · e-Laws consolidated snapshot

9.30.3. — Wood Strip Flooring

Content not available for this version.

9.30.3.1. — Thickness

(1) The thickness of wood strip flooring shall conform to Table 9.30.3.1.

Text · e-Laws consolidated snapshot

Table 9.30.3.1. Thickness of Wood Strip Flooring Forming Part of Sentence 9.30.3.1.(1)

Column 1

Column 2

Column 3

Column 4

Type of Flooring

Maximum Joist Spacing, mm

Minimum Thickness of Flooring, mm

With Subfloor

No Subfloor

Matched hardwood (interior use only)

400

7.9

19.0

600

7.9

33.3

Matched softwood (interior or exterior use)

400

19.0

19.0

600

19.0

31.7

Square edge softwood (exterior use only)

400

25.4

600

38.1

9.30.3.2. — Strip Direction and End Joints

(1) Wood strip flooring shall not be laid parallel to lumber subflooring unless a separate underlay is provided.

(2) If wood strip flooring is applied without a subfloor, it shall be laid at right angles to the joists so that the end joints are staggered and occur over supports or are end matched.

(3) If the flooring is end matched, it shall be laid so that no 2 adjoining strips break joints in the same space between supports and each strip bears on no fewer than 2 supports.

Text · e-Laws consolidated snapshot

9.30.3.3. — Nailing

(1) When nails are used, wood strip flooring shall be toe nailed or face nailed with at least 1 nail per strip at the spacings shown in Table 9.30.3.3., except that face nailed strips of more than 25 mm in width shall have at least 2 nails per strip.

(2) Face nails shall be countersunk.

Editor's note

In the notes to Table-9.30.3.3., the footnote reference numbers are presented inline with a separating space; the e-Laws consolidation renders them as superscript abutting the text. The footnote text is identical.

Text · e-Laws consolidated snapshot

Table 9.30.3.3. Nailing of Wood Strip Flooring Forming Part of Sentence 9.30.3.3.(1)

Column 1

Column 2

Column 3

Finish Floor Thickness, Mm

Minimum Length of Flooring Nails, mm

Maximum Spacing of Flooring Nails, mm

7.9

38(1)

200

11.1

51

300

19.0

57

400

25.4

63

400

31.7

70

600

38.1

83

600

Notes to Table 9.30.3.3.:

(1)See Article 9.30.3.4.

9.30.3.4. — Staples

(1) Staples are permitted to be used to fasten wood strip flooring not more than 7.9 mm in thickness and not more than 50 mm in width provided the staples,

(a) are not less than 29 mm long,

(b) have a shank diameter of not less than 1.19 mm,

(c) have a crown of not less than 4.7 mm, and

(d) are spaced not more than 400 mm o.c.

(2) Staples are permitted to be used to fasten wood strip flooring not more than 19 mm in thickness and not more than 83 mm in width provided the staples,

(a) are not less than 51 mm long,

(b) have a shank diameter of not less than 1.82 mm,

(c) have a crown of not less than 12.7 mm, and

(d) are spaced not more than 400 mm o.c.

Text · e-Laws consolidated snapshot

9.30.4. — Parquet Flooring

Content not available for this version.

9.30.4.1. — Adhesive

(1) Adhesive used to attach parquet block flooring shall be suitable for bonding wood to the applicable subfloor material.

Text · e-Laws consolidated snapshot

9.30.5. — Resilient Flooring

Content not available for this version.

9.30.5.1. — Materials

(1) Resilient flooring used on concrete slabs supported on ground shall consist of asphalt, rubber, vinyl-asbestos, unbacked vinyl or vinyl with an inorganic type backing.

(2) Flooring described in Sentence (1) shall be attached to the base with a suitable waterproof and alkali-resistant adhesive.

Text · e-Laws consolidated snapshot

9.30.6. — Ceramic Tile

Content not available for this version.

9.30.6.1. — Application

(1) Ceramic tile shall be set in a mortar bed or applied to a sound smooth base with a suitable adhesive.

(2) Panel-type subfloor to which ceramic tile is to be applied with adhesive shall have its edges supported according to Article 9.23.14.3.

Text · e-Laws consolidated snapshot

9.30.6.2. — Ceramic Tile Set in Mortar Bed

(1) When ceramic tile is set in mortar bed, the bed shall be not less than 32 mm thick. A 50 mm by 50 mm galvanized wire mesh shall be placed in the mortar bed, and asphalt sheathing paper, felt or polyethylene film shall be applied under the mortar bed when the mortar is applied over wood subfloors.

(2) The mortar bed described in Sentence (1) shall consist of by volume,

(a) 1 part Portland cement,

(b) 4 parts sand, and

(c) 1 part water.

(3) The tile joints for the ceramic tile in Sentence (1) shall be grouted with cement grout which shall be compressed into joints between the tiles and then wiped smooth.

Text · e-Laws consolidated snapshot

9.30.6.3. — Reinforcement for Panel-Type Wood Sheathing

(1) Except as permitted in Article 9.30.6.4.v1, when ceramic floor tiles are set on panel-type wood sheathing, one of the following assemblies for reinforcing the floor assembly shall be used:

(a) 20 mm thick plywood or waferboard with all edges supported by at least 38 mm by 38 mm blocking with floor joists spaced not more than 400 mm o.c., with 6 mm underlay,

(b) sheathing with a thickness that conforms to Table 9.23.14.5.A. or a rating that complies to Table 9.23.14.5.B. and has an underlay consisting of 15.9 mm plywood or waferboard with offsetting joints, with a 4 mm gap between the sheets, or

(c) subfloor sheathing reinforced with close spaced 38 mm by 38 mm blocking at spacings at least half that of the floor joist spacing.

Text · e-Laws consolidated snapshot

9.30.6.4. — Ceramic Tile Applied to Mortar Bed with Adhesive

(1) When ceramic tile is applied to a mortar bed with adhesive, the bed shall be not less than 12.5 mm thick.

(2) The mortar bed described in Sentence (1) shall consist of by volume,

(a) 1 part Portland cement,

(b) 3 parts sand, and

(c) 1 part water.

(3) At least one layer of galvanized diamond mesh wire lath shall be imbedded in the mortar bed.

(4) Joints in the wire lath required by Sentence (3) shall be overlapped not less than 12 mm.

(5) The wire lath required in Sentence (3) shall be fastened to the subfloor with,

(a) lath nails not less than 38 mm length spaced not more than 150 mm o.c., or

(b) staples not less than 38 mm in length spaced not more than 150 mm o.c.

(6) Asphalt sheathing paper, felt or polyethylene film shall be applied between the mortar bed and the wood subfloor.

(7) Floor joists supporting the mortar bed described in Sentence (1) shall,

(a) be spaced not more than 400 mm o.c., and

(b) have no fewer than two rows of 38 mm × 38 mm cross bridging.

(8) The tile joints for the ceramic tile in Sentence (1) shall be grouted with cement grout which shall be compressed into joints between the tiles and then wiped smooth.