9.30.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.30.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.30.1. — Pro

9.30.1. — General

Content not available for this version.

9.30.1.1. — Required Finish Flooring

(1) Finished flooring shall be provided in all residential occupancies.

Text · e-Laws consolidated snapshot

9.30.1.2. — Water Resistance

(1) Finished flooring in bathrooms, kitchens, public entrance halls, laundry and general storage areas shall consist of resilient flooring, felted-synthetic-fibre floor coverings, concrete, terrazzo, ceramic tile, mastic or other types of flooring providing similar degrees of water resistance.

Text · e-Laws consolidated snapshot

9.30.1.3. — Sleepers

(1) Wood sleepers supporting finished flooring over a concrete base supported on the ground shall be not less than 19 mm by 38 mm and shall be treated with a wood preservative.

Text · e-Laws consolidated snapshot

9.30.1.4. — Finish Quality

(1) Finished flooring shall have a surface that is smooth, even and free from roughness or open defects.