OBC 2006 › Division B
9.9.7.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.9.7.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.9.7.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.9.7. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.9.7. — Pro
9.9.7. — Access to Exits
Content not available for this version.
9.9.7.1. — Egress from Roof Area, Podiums, Terraces, Platforms and Contained Open Spaces
(1) An access to exit shall be provided from every roof intended for occupancy and from every podium, terrace, platform or contained open space.
(2) Where a roof is intended for an occupant load of more than 60 persons, at least 2 separate means of egress shall be provided from the roof to stairs designed in conformance with the requirements for exit stairs and located remote from each other.
(3) Where a podium, terrace, platform or contained open space is provided, egress requirements shall conform to the appropriate requirements for rooms or suites in Article 9.9.7.4.
Text · e-Laws consolidated snapshot
9.9.7.2. — Means of Egress from Suites
(1) Except as required in Sentence 9.9.9.3.(1), each suite in a floor area occupied by more than one suite shall have,
(a) an exterior exit doorway,
(b) a doorway to a public corridor, or
(c) a doorway to exterior passageway.
(2) Except as provided in Sentences 9.9.7.3.(1) and 9.9.8.2.(2), from the point where a doorway described in Clauses (1)(b) or (c) enters the public corridor or exterior passageway, it shall be possible to go in opposite directions to each of 2 separate exits.
Editor's note
As filed in O. Reg. 350/06, Sentence (2) cites 'Clauses (1)(b) or (c)' using the plural 'Clauses'; the consolidated e-Laws text renders the reference word in the singular ('Clause'). No amending regulation makes this change; the as-filed wording is retained here.
9.9.7.3. — Dead End Corridors
(1) A dead-end public corridor is permitted in an occupancy shown in Table 9.9.7.3. where,
(a) a dead-end corridor,
(i) does not exceed the distance of travel measured from the most remote point of the dead-end to a point where it is possible to go in opposite directions to each of two separate exits, and
(ii) is provided with doors equipped with self-closing devices, or
(b) there is a second and separate egress doorway from each room or suite not leading into the dead-end corridor.
(2) Dead-end public corridors in residential occupancies and business and personal services occupancies shall contain only suite door openings arranged so that not more than 2 such doors have to be passed to reach the nearest exit.
(3) The area of wired glass in doors required by Sentence (2) shall not exceed 645 cm².
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 |
Occupancy | Maximum Length of Dead-End Public Corridor, m | Maximum Occupant Load or Suites Served by Dead-End Public Corridor |
Group C | 6 | 4 suites |
Group D | 6 | 30 |
Group E | 9 | 30 |
Group F | 9 | 30 |
9.9.7.4. — Number and Spacing of Egress Doors
(1) Except for dwelling units, at least 2 egress doors shall be provided where,
(a) the area of a room or suite exceeds 200 m² in a Group D, E, F2 and F3 occupancy, or 150 m² in a Group C occupancy, or
(b) the distance measured from any point within a room or suite to the nearest egress door exceeds 25 m.
(2) Doors in Sentence (1) shall be spaced so that in the event one door is made inaccessible by a fire within such a room or suite, the other door will provide safe egress.
Text · e-Laws consolidated snapshot
9.9.7.5. — Independent Access to Exit
(1) Required access to exit from suites shall not be through any other dwelling unit, service room or other occupancy.
Text · e-Laws consolidated snapshot
9.9.7.6. — Travel Distance within Rooms and Suites
(1) Except for dwelling units, the travel distance from any point within the room or suite to the nearest egress door shall not exceed the maximum travel distance in Article 9.9.8.2.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 9.9.7. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.9.7. — Pro