9.9.9.3. — Shared Egress Facilities

(1) A dwelling unit shall be provided with a second and separate means of egress where an egress door from the dwelling unit opens onto,

(a) an exit stairway serving more than 1 suite,

(b) a public corridor serving more than one suite served by a single exit stairway,

(c) an exterior passageway more than 1 500 mm above adjacent ground level, serving more than one suite and served by a single exit stairway, or

(d) a balcony more than 1 500 mm above adjacent ground level, serving more than one suite and served by a single exit stairway.

Text · e-Laws consolidated snapshot