9.9.7.2. — Means of Egress from Suites

(1) Except as required in Sentence 9.9.9.3.(1), each suite in a floor area occupied by more than one suite shall have,

(a) an exterior exit doorway,

(b) a doorway to a public corridor, or

(c) a doorway to exterior passageway.

(2) Except as provided in Sentences 9.9.7.3.(1) and 9.9.8.2.(2), from the point where a doorway described in Clauses (1)(b) or (c) enters the public corridor or exterior passageway, it shall be possible to go in opposite directions to each of 2 separate exits.

Editor's note

As filed in O. Reg. 350/06, Sentence (2) cites 'Clauses (1)(b) or (c)' using the plural 'Clauses'; the consolidated e-Laws text renders the reference word in the singular ('Clause'). No amending regulation makes this change; the as-filed wording is retained here.