OBC 2006 › Division B
7.6.4.2.
Version 1 — in force 1 January 2011
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.6.4.2.
- Version
- v1
(6) Section 114 comes into force on January 1, 2011.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(6)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.6.4.2.
- Version
- v1
(6) Section 114 comes into force on January 1, 2011.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(6)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 7.6.4.2. — Pro
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 503/09, cl. 114 · ext ← current
In force 2011-01-01
OBC 2012 · continues as 7.6.4.2. — Pro
7.6.4.2. — Plumbing Fixtures
Comparing versions
Changed text stands out · unchanged is dimmed
v0 base
Earlier · 2006-12-31(1) Water closets and urinals shall be certified to CAN/CSA-B45.0, “General Requirements for Plumbing Fixtures”.
(2) The flush cycle for each fixture that is a water closet or urinal and that is installed as a replacement for a fixture in a building that existed before the 1st day of January 1996 shall not exceed the maximum flush cycle listed for that fixture in Table 7.6.4.2.A.
(3) Except as provided in Sentence (2) the flush cycle for each fixture that is a water closet or urinal shall not exceed the maximum flush cycle listed for that fixture in Table 7.6.4.2.B.
(4) Sentences (2) and (3) do not apply to a fixture located in a heritage building, care or detention occupancy or passenger station.
v1 O. Reg. 503/09
Later · viewing · 2011-01-01(1) Water closets and urinals shall be certified to CAN/CSA-B45.0, “General Requirements for Plumbing Fixtures”.
(2) The flush cycle for each fixture that is a water closet or urinal shall not exceed the maximum flush cycle listed for that fixture in Table 7.6.4.2.
(3) Sentence (2) does not apply to a fixture located in an existing building where the chief building official is satisfied that compliance with the requirement is impracticable because of maintenance or operational difficulties.
(4) Revoked: O. Reg. 503/09, s. 114.
Provenance
OBC 1997 · continues from 7.6.4.2. — Pro
Base · O. Reg. 350/06 · ext v0 → comparing ×
O. Reg. 503/09, cl. 114 · ext ← current
In force 2011-01-01
OBC 2012 · continues as 7.6.4.2. — Pro