(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.6.4.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 7.6.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 7.6.4. — Pro
7.6.4. — Water Efficiency
Content not available for this version.
7.6.4.1. — Water Supply Fittings
(1) The flow rates of fittings that supply water to a fixture shall not exceed the maximum flow rates at the test pressures listed for that fitting in Table 7.6.4.1.
(2) Sentence (1) does not apply to a fixture located in a heritage building.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 |
Fitting | Maximum Flow, L/min | Test Pressure, kPa |
Lavatory Faucet | 8.35 | 413 |
Kitchen Faucet | 8.35 | 413 |
Shower Heads | 9.5 | 550 |
7.6.4.2. — Plumbing Fixtures
(1) Water closets and urinals shall be certified to CAN/CSA-B45.0, “General Requirements for Plumbing Fixtures”.
(2) The flush cycle for each fixture that is a water closet or urinal and that is installed as a replacement for a fixture in a building that existed before the 1st day of January 1996 shall not exceed the maximum flush cycle listed for that fixture in Table 7.6.4.2.A.
(3) Except as provided in Sentence (2) the flush cycle for each fixture that is a water closet or urinal shall not exceed the maximum flush cycle listed for that fixture in Table 7.6.4.2.B.
(4) Sentences (2) and (3) do not apply to a fixture located in a heritage building, care or detention occupancy or passenger station.
Editor's note
In the notes to Table-7.6.4.2.A., Table-7.6.4.2.B., the footnote reference numbers are presented inline with a separating space; the e-Laws consolidation renders them as superscript abutting the text. The footnote text is identical.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 |
Fixture | litres |
Water Closet (Tank Type) | 13.25 |
Water Closet (Direct Flush) | 13.25 |
Urinal (Tank Type) | 5.68(1) |
Urinal (Direct Flush) | 5.68(1) |
Notes to Table 7.6.4.2.A.:
(1)Urinals equipped with automatic flushing devices shall be controlled to prevent unnecessary flush cycles during building down time.
Column 1 | Column 2 |
Fixture | litres |
Water Closet (Tank Type) | 6 |
Water Closet (Direct Flush) | 6 |
Urinal (Tank Type) | 3.8(1) |
Urinal (Direct Flush) | 3.8(1) |
Notes to Table 7.6.4.2.B.:
(1)Urinals equipped with automatic flushing devices shall be controlled to prevent unnecessary flush cycles during building down time.