7.6.4.1. — Water Supply Fittings

(1) The flow rates of fittings that supply water to a fixture shall not exceed the maximum flow rates at the test pressures listed for that fitting in Table 7.6.4.1.

(2) Sentence (1) does not apply to a fixture located in a heritage building.

Text · e-Laws consolidated snapshot

Table 7.6.4.1. Maximum Flow Rates for Water Supply Fittings Forming Part of Sentence 7.6.4.1.(1)

Column 1

Column 2

Column 3

Fitting

Maximum Flow, L/min

Test Pressure, kPa

Lavatory Faucet

8.35

413

Kitchen Faucet

8.35

413

Shower Heads

9.5