7.6.4.2. — Plumbing Fixtures

(1) Water closets and urinals shall be certified to CAN/CSA-B45.0, “General Requirements for Plumbing Fixtures”.

(2) The flush cycle for each fixture that is a water closet or urinal shall not exceed the maximum flush cycle listed for that fixture in Table 7.6.4.2.

(3) Sentence (2) does not apply to a fixture located in an existing building where the chief building official is satisfied that compliance with the requirement is impracticable because of maintenance or operational difficulties.

(4) Revoked: O. Reg. 503/09, s. 114.

Editor's note

The e-Laws consolidation displays a heading marking Table 7.6.4.2.B. as revoked; this map does not reproduce that redundant heading.

Table 7.6.4.2. Maximum Flush Cycles for Sanitary Fixtures Forming Part of Sentence 7.6.4.2.(2)

Column 1

Column 2

Fixture

Litres

Water Closet (Tank Type)

6

Water Closet (Direct Flush)

6

Urinal (Tank Type)

3.8(1)

Urinal (Direct Flush)

3.8(1)

Notes to Table 7.6.4.2.:

(1)Urinals equipped with automatic flushing devices shall be controlled to prevent unnecessary flush cycles during building down time.