9.36.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.36. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.36. — Pro

9.36. — Cottages

Content not available for this version.

9.36.1. — Scope

Content not available for this version.

9.36.1.1. — Application

(1) This Section applies to buildings of residential occupancy used or intended to be used as seasonal recreational buildings.

(2) The buildings described in Sentence (1) shall comply with all the requirements of this Part, except where they are specifically exempted in this Section.

Text · e-Laws consolidated snapshot

9.36.2. — General

Content not available for this version.

9.36.2.1. — Exclusions

(1) Except as provided in Articles 9.36.3.1. and 9.36.2.4. and Subsection 9.10.15., buildings used or intended to be used as seasonal recreational buildings need not comply with Sections 9.5. to 9.7. and 9.9. to 9.11.

(2) Flooring need not comply with Section 9.30., but tight-fitting floors shall be provided to support the live and dead loads.

(3) Except as provided in Sentences (4) and (5), thermal insulation, vapour barrier, air-barrier construction, interior finishes, plumbing, heating, mechanical ventilation, air-conditioning and electrical facilities, need not be provided, but where any of these are provided, they shall comply with the requirements of this Part.

(4) Where heating and air-conditioning are provided, Article 9.33.3.1. need not be complied with.

(5) Where thermal insulation is provided, the minimum thermal resistance of insulation in Table 9.25.2.1. need not be provided.

Text · e-Laws consolidated snapshot

9.36.2.2. — Foundations

(1) Continuous perimeter foundation walls are not required, but when they are provided, they shall comply with the requirements of this Part.

(2) Where unit masonry columns are used, the height of such columns shall not exceed,

(a) in the case of hollow masonry units, 4 times the least dimension of the units,

(b) in the case of solid masonry units or hollow units with voids filled with concrete, 10 times the least dimension of the column, or

(c) where the column is reinforced with at least four 13 mm diameter bars and filled with concrete, 18 times the least dimension of the column.

(3) Columns in excess of the height limitations of Clauses (2)(a) to 2(c) shall be designed in accordance with Part 4.

Editor's note

As filed in O. Reg. 350/06, Sentence (3) cites 'Clauses (2)(a) to 2(c)', with a stray '2' before the closing '(c)'; the consolidated e-Laws text renders the range end in the standard form 'to (c)'. No amending regulation makes this change; the as-filed wording is retained here.

9.36.2.3. — Waterproofing and Dampproofing

(1) Where foundations below ground level and concrete floors on ground are used, they shall comply with Section 9.13.

Text · e-Laws consolidated snapshot

9.36.2.4. — Smoke Alarms

(1) Every dwelling unit within the scope of this Section shall be provided with a smoke alarm in accordance with Subsection 9.10.19.

Text · e-Laws consolidated snapshot

9.36.3. — Tourist Accommodation

Content not available for this version.

9.36.3.1. — Buildings for Seasonal Tourist Accommodation or for Rent

(1) Where buildings are used or intended to be used for seasonal tourist accommodation or for rent, they shall comply with Sections 9.5. to 9.8. in addition to the requirements of this Section.

Text · e-Laws consolidated snapshot