CodeChronicle

OBC 2006 Division B

9.12.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.12. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.12. — Pro

9.12. — Excavation

Content not available for this version.

9.12.1. — General

Content not available for this version.

9.12.1.1. — Removal of Topsoil and Organic Matter

(1) The topsoil and vegetable matter in all unexcavated areas under a building shall be removed.

(2) In localities where termite infestation is known to be a problem, all stumps, roots and other wood debris shall be removed from the soil to a depth of not less than 300 mm in unexcavated areas under a building.

(3) The bottom of every excavation shall be free of all organic material.

Text · e-Laws consolidated snapshot

9.12.1.2. — Standing Water

(1) Excavations shall be kept free of standing water.

Text · e-Laws consolidated snapshot

9.12.1.3. — Protection from Freezing

(1) The bottom of excavations shall be kept from freezing throughout the entire construction period.

Text · e-Laws consolidated snapshot

9.12.1.4. — Precautions During Excavation

(1) Every excavation shall be undertaken in such a manner to prevent damage to adjacent property, existing structures, utilities, roads and sidewalks at all stages of construction.

(2) Material shall not be placed nor shall equipment be operated or placed in or adjacent to an excavation in a manner that may endanger the integrity of the excavation or its supports.

Text · e-Laws consolidated snapshot

9.12.2. — Depth

Content not available for this version.

9.12.2.1. — Excavation to Undisturbed Soil

(1) Excavations for foundations shall extend to undisturbed soil.

Text · e-Laws consolidated snapshot

9.12.2.2. — Minimum Depth of Foundations

(1) Except as provided in Sentences (4) and (5), the minimum depth of foundations below finished ground level shall conform to Table 9.12.2.2.

(2) Where a foundation is insulated in a manner that will reduce the heat flow to the soil beneath the footings, the foundation depth shall conform to that required for foundations containing no heated space.

(3) The minimum depth of foundations for exterior concrete steps with more than 2 risers shall conform to Sentences (1), (2) and (5).

(4) Concrete steps with 1 and 2 risers are permitted to be laid on ground level.

(5) The foundation depths required in Sentence (1) are permitted to be decreased where experience with local soil conditions shows that lesser depths are satisfactory, or where the foundation is designed for lesser depths.

(6) The foundation depths required in Sentence (1) do not apply to foundations for,

(a) buildings,

(i) that are not of masonry or masonry veneer construction, and

(ii) whose superstructure conforms with the requirements of the deformation resistance test in CAN/CSA-Z240.2.1, “Structural Requirements for Mobile Homes”, or

(b) accessory buildings,

(i) that are not of masonry or masonry veneer construction.,

(ii) not more than 1 storey in building height,

(iii) not more than 55 m² in building area, and

(iv) where the distance from the finished ground to the underside of the floor joists is not more than 600 mm.

(7) The foundation depths required in Sentence (1) do not apply to foundations for decks and other accessible exterior platforms,

(a) that are of not more than 1 storey,

(b) that are not more than 55 m² in area,

(c) where the distance from the finished ground to the underside of the floor joists is not more than 600 mm,

(d) that are not supporting a roof, and

(e) that are not attached to another structure, unless it can be demonstrated that differential movement will not adversely affect the performance of that structure.

Editor's note

In the notes to Table-9.12.2.2., the footnote reference numbers are presented inline with a separating space; the e-Laws consolidation renders them as superscript abutting the text. The footnote text is identical.

Note As filed, the footnote markers in the notes of Table-9.12.2.2. are set with a following space (e.g. '(5) "N" is…'); the e-Laws consolidation renders them without it. The note text is otherwise identical between the two renderings.

Text · e-Laws consolidated snapshot

Table 9.12.2.2. Minimum Depths of Foundations Forming Part of Sentence 9.12.2.2.(1)

Column 1

Column 2

Column 3

Column 4

Column 5

Type of Soil

Minimum Depth of Foundation Containing Heated Basement or Crawl Space(1)

Minimum Depth of Foundation Containing no Heated Space(2)

Good Soil Drainage(3)

Poor Soil Drainage

Good Soil Drainage(3)

Poor Soil Drainage

Rock

No limit

No limit

No limit

No limit

Coarse grained soils

No limit

No limit

No limit

Below the depth of frost penetration

Silt

No limit

No limit

Below the depth of frost penetration

Below the depth of frost penetration

Clay or soils not clearly defined

1.2 m

1.2 m

1.2 m but not less than the depth of frost penetration

1.2 m but not less than the depth of frost penetration

Notes to Table 9.12.2.2.:

(1) Foundation not insulated to reduce heat loss through the footings.

(2) Including foundations containing heated space insulated to reduce heat loss through the footings.

(3) Good soil drainage to not less than the depth of frost penetration.

9.12.3. — Backfill

Content not available for this version.

9.12.3.1. — Placement of Backfill

(1) Backfill shall be placed to avoid damaging the foundation wall, the drainage tile, drainage layer, externally applied thermal insulation, waterproofing and dampproofing of the wall.

Text · e-Laws consolidated snapshot

9.12.3.2. — Grading of Backfill

(1) Backfill shall be graded to prevent drainage towards the foundation after settling.

Text · e-Laws consolidated snapshot

9.12.3.3. — Deleterious Debris and Boulders

(1) Backfill within 600 mm of the foundation shall be free of deleterious debris and boulders larger than 250 mm diam.

(2) Except as permitted in Sentence (3), backfill shall not contain pyritic material or material that is susceptible to ice lensing in concentrations that will damage the building to a degree that would adversely affect its stability or the performance of assemblies separating dissimilar environments.

(3) Backfill with material of any concentration that is susceptible to ice lensing is permitted where foundation walls are cast-in-place concrete, concrete block insulated on the exterior or concrete block protected from the backfill by a material that serves as a slip plane.

Text · e-Laws consolidated snapshot

9.12.3.4. — Lateral Support of Foundation Wall

(1) Where the height of foundation wall is such that lateral support is required, or where the required concrete strength of the wall has not been reached, the wall shall be braced or laterally supported before backfilling.

Text · e-Laws consolidated snapshot

9.12.4. — Trenches Beneath Footings

Content not available for this version.

9.12.4.1. — Compacting or Filling With Concrete

(1) The soil in trenches beneath footings for sewers and watermains shall be compacted by tamping up to the level of the footing base, or shall be filled with concrete having a strength not less than 10 MPa to support the footing.

Text · e-Laws consolidated snapshot