4.1.8.6. — Structural Configuration

Comparing versions

Changed text stands out · unchanged is dimmed

v0 base

Earlier · 2006-12-31

(1) Structures having any of the features listed in Table 4.1.8.6. shall be designated irregular.

(2) Structures not classified as irregular according to Sentence 4.1.8.6.(1) may be considered regular.

(3) Except as required by Article 4.1.8.10., in cases where IEFaSa(0.2) is equal to or greater than 0.35, structures designated as irregular must satisfy the provisions referenced in Table 4.1.8.6.

v1 O. Reg. 503/09

Later · viewing · 2010-01-01

(1) Structures having any of the features listed in Table 4.1.8.6. shall be designated irregular.

(2) Structures not classified as irregular according to Sentence 4.1.8.6.(1) may be considered regular.

(3) Except as required by Article 4.1.8.10., in cases where IEFaSa(0.2) is equal to or greater than 0.35, structures designated as irregular must satisfy the provisions referenced in Table 4.1.8.6.