OBC 2006 › Division B
4.1.8.6.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 4.1.8.6.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 4.1.8.6.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
Provenance
New in this edition — no OBC 1997 predecessor
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 59 · ext v1 →
In force 2010-01-01
Next: O. Reg. 503/09, cl. 59 · ext (not in force until 2010-01-01) v1 →
OBC 2012 · continues as 4.1.8.6. — Pro
4.1.8.6. — Structural Configuration
(1) Structures having any of the features listed in Table 4.1.8.6. shall be designated irregular.
(2) Structures not classified as irregular according to Sentence 4.1.8.6.(1) may be considered regular.
(3) Except as required by Article 4.1.8.10., in cases where IEFaSa(0.2) is equal to or greater than 0.35, structures designated as irregular must satisfy the provisions referenced in Table 4.1.8.6.
Editor's note
Table-4.1.8.6. — This map follows the as-filed text of O. Reg. 350/06 for the notes to Table 4.1.8.6. of Division B. The as-filed renders each of the six note numbers — '(1)' through '(6)' — as a superscript followed by a space, and the 'Notes to Table 4.1.8.6.:' headnote in bold; the e-Laws consolidation renders each note number in plain text with no following space and the headnote in plain text (for example, '(1) One-storey' becomes '(1)One-storey'). Neither change is made by any amending regulation, and the note text is unchanged. This map preserves the as-filed rendering.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 |
Type | Irregularity Type and Definition | Notes |
Vertical Stiffness Irregularity | ||
1 | Vertical stiffness irregularity shall be considered to exist when the lateral stiffness of the SFRS in a storey is less than 70% of the stiffness of any adjacent storey, or less than 80% of the average stiffness of the three storeys above or below. | (2)(3) |
Weight (mass) Irregularity | (2) | |
2 | Weight irregularity shall be considered to exist where the weight, Wi, of any storey is more than 150% of the weight of an adjacent storey. A roof that is lighter than the floor below need not be considered. | |
Vertical Geometric Irregularity | (2)(3)(4) | |
3 | Vertical geometric irregularity shall be considered to exist where the horizontal dimension of the SFRS in any storey is more than 130% of that in an adjacent storey. | |
In-Plane Discontinuity in Vertical Lateral-Force-Resisting Element | ||
4 | An in-plane offset of a lateral-force-resisting element of the SFRS or a reduction in lateral stiffness of the resisting element in the storey below. | (2)(3)(4) |
Out-of-Plane Offsets | ||
5 | Discontinuities in a lateral force path, such as out-of-plane offsets of the vertical elements of the SFRS. | (2)(3)(4) |
Discontinuity in Capacity – Weak Storey | ||
6 | A weak storey is one in which the storey shear strength is less than that in the storey above. The storey shear strength is the total strength of all seismic-resisting elements of the SFRS sharing the storey shear fo the direction under consideration. | (3) |
Torsional Sensitivity (to be considered when diaphragms are not flexible) | ||
7 | Torsional sensitivity shall be considered to exist when the ratio B calculated according to Sentence 4.1.8.11.(9) exceeds 1.7. | (2)(3)(5) |
Non-orthogonal Systems | ||
8 | A non-orthogonal system irregularity shall be considered to exist when the SFRS is not oriented along a set of orthogonal axes. | (6) |
Notes to Table 4.1.8.6.:
(1) One-storey penthouses with a weight of less than 10% of the level below need not be considered in the application of this Table.
(2) See Article 4.1.8.7.
(3) See Article 4.1.8.10.
(4) See Article 4.1.8.15.
(5) See Sentences 4.1.8.11.(9), (10) and 4.1.8.12.(4).
(6) See Article 4.1.8.8.
Provenance
New in this edition — no OBC 1997 predecessor
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 59 · ext v1 →
In force 2010-01-01 compare
Next: O. Reg. 503/09, cl. 59 · ext (not in force until 2010-01-01) v1 →
OBC 2012 · continues as 4.1.8.6. — Pro