CodeChronicle

OBC 2006 Division B

9.9.6.3.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · split from 9.9.6.1. — Pro

OBC 1997 · split from 9.9.6.4. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

O. Reg. 503/09, cl. 140 · ext v1 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 140 · ext (not in force until 2010-01-01) v1 →

OBC 2012 · continues as 9.9.6.3. — Pro

9.9.6.3. — Clear Opening Width at Doorways

Comparing versions

Changed text stands out · unchanged is dimmed

v0 base

Earlier · viewing · 2006-12-31

(1) Except as provided in Sentence (4), the clear opening width of doorways shall comply with Sentence (2) at,

(a) exit doors, and

(b) doors that open into or are located within a public corridor, or

(c) doors that open into or are located within another facility that provides access to exit from a suite.

(2) Doorways described in Sentence (1) shall be not less than,

(a) 800 mm wide where there is only one door leaf,

(b) 800 mm wide where multiple-leaf doors are installed with only one active leaf with a latching mechanism described in Article 9.9.6.7, and

(c) 1210 mm wide where multiple-leaf doors are installed with two active leaves.

(3) In doorways described in Sentence (1) that have multiple-leaf doors installed,

(a) no active leaf shall be less than 810 mm wide where only one leaf is active, and

(b) no single leaf shall be less than 610 mm wide where two leaves are active.

(4) Doorways serving a single dwelling unit need not comply with Sentence (2).

v1 O. Reg. 503/09

Later · 2010-01-01

(1) Except as provided in Sentence (4), the clear opening width of doorways shall comply with Sentence (2) at,

(a) exit doors, and

(b) doors that open into or are located,

(i) within a public corridor, or

(ii) within another facility that provides access to exit from a suite.

(c) Revoked: O. Reg. 503/09, s. 140.

(2) Doorways described in Sentence (1) shall be not less than,

(a) 800 mm wide where there is only one door leaf,

(b) 800 mm wide where multiple-leaf doors are installed with only one active leaf with a latching mechanism described in Article 9.9.6.7, and

(c) 1210 mm wide where multiple-leaf doors are installed with two active leaves.

(3) In doorways described in Sentence (1) that have multiple-leaf doors installed,

(a) no active leaf shall be less than 810 mm wide where only one leaf is active, and

(b) no single leaf shall be less than 610 mm wide where two leaves are active.

(4) Doorways serving a single dwelling unit need not comply with Sentence (2).