OBC 2006 › Division B
9.6.3.1.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.6.3.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.6.3.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
Provenance
OBC 1997 · continues from 9.6.3.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 137/07, cl. 45 · ext v1 →
In force 2007-04-02
Next: O. Reg. 137/07, cl. 45 · ext (not in force until 2007-04-02) v1 →
OBC 2012 · renumbered to 9.5.11.1. — Pro
9.6.3.1. — Doorway Opening Sizes
(1) Except as provided in Articles 9.6.3.3., 9.9.6.2. and 9.9.6.3., doorway openings within dwelling units shall be designed to accommodate at least the door sizes in Table 9.6.3.1. for swing-type doors or folding doors.
Editor's note
In the notes to Table-9.6.3.1., the footnote reference numbers are presented inline with a separating space; the e-Laws consolidation renders them as superscript abutting the text. The footnote text is identical.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 |
At Entrance to: | Minimum Width, mm | Minimum Height, mm |
Dwelling unit (required entrance) | 810 | 1 980 |
Vestibule or entrance hall | ||
Stairs to a floor level that contains a finished space | 810 | 1 980 |
All doors in at least one line of passage from the exterior to the basement | ||
Utility rooms | ||
Walk-in closet | 610 | 1 980 |
Bathroom, water closet room, shower room(1) | 610 | 1 980 |
Rooms located off hallways that are permitted to be 710 mm wide | 610 | 1 980 |
Rooms not mentioned above, exterior balconies | 760 | 1 980 |
Notes to Table 9.6.3.1.:
(1)See Article 9.6.3.3.
Provenance
OBC 1997 · continues from 9.6.3.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 137/07, cl. 45 · ext v1 →
In force 2007-04-02 compare
Next: O. Reg. 137/07, cl. 45 · ext (not in force until 2007-04-02) v1 →
OBC 2012 · renumbered to 9.5.11.1. — Pro