OBC 2006 › Division B
9.26.9.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.26.9.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.26.9.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.26.9. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.26.9. — Pro
9.26.9. — Wood Roof Shingles
Content not available for this version.
9.26.9.1. — Decking
(1) Decking for wood shingled roofs may be continuous or spaced.
Text · e-Laws consolidated snapshot
9.26.9.2. — Grade
(1) Western cedar shingles shall be not less than No. 2 grade.
(2) Eastern white cedar shingles shall be not less than B (clear) grade.
Text · e-Laws consolidated snapshot
9.26.9.3. — Size
(1) Wood shingles shall be not less than 400 mm long and not less than 75 mm nor more than 350 mm wide.
Text · e-Laws consolidated snapshot
9.26.9.4. — Spacing and Joints
(1) Shingles shall be spaced approximately 6 mm apart and offset at the joints in adjacent courses not less than 40 mm so that joints in alternate courses are staggered.
Text · e-Laws consolidated snapshot
9.26.9.5. — Fastening
(1) Shingles shall be fastened with 2 nails or staples located approximately 20 mm from the sides of the shingle and 40 mm above the exposure line.
Text · e-Laws consolidated snapshot
9.26.9.6. — Exposure
(1) The exposure of wood roof shingles shall conform to Table 9.26.9.6.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 | Column 4 | Column 5 | Column 6 | Column 7 |
Roof Slope | Maximum Exposure, mm | |||||
No. 1 or A Grade Length of Shingle, mm | No. 2 or B Grade Length of Shingle, mm | |||||
400 | 450 | 600 | 400 | 450 | 600 | |
<1 in 3 | 100 | 115 | 165 | 90 | 100 | 140 |
≥1 in 3 | 125 | 140 | 190 | 100 | 115 | 165 |
9.26.9.7. — Flashing
(1) Flashing shall conform to Subsection 9.26.4.
Text · e-Laws consolidated snapshot
9.26.9.8. — Eave Protection
(1) Eave protection shall conform to Subsection 9.26.5.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 9.26.9. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.26.9. — Pro