OBC 2006 › Division B
9.26.8.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.26.8.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.26.8.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.26.8. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.26.8. — Pro
9.26.8. — Asphalt Shingles on Slopes of Less Than 1 in 3
Content not available for this version.
9.26.8.1. — Coverage
(1) Except for the first 2 courses, coverage shall be not less than 3 thicknesses of shingle over the entire roof, disregarding cutouts.
Text · e-Laws consolidated snapshot
9.26.8.2. — Starter Strip
(1) A starter strip shall be installed as in Article 9.26.7.2.
(2) Starter strips required in Sentence (1) shall be laid in a continuous band of cement not less than 200 mm wide.
Text · e-Laws consolidated snapshot
9.26.8.3. — Securing of Tabs
(1) Shingle tabs shall be secured with cold application cement applied at the rate of not less than 0.5 L/m² of cemented area, or hot application asphalt applied at the rate of 1 kg/m² of cemented area.
Text · e-Laws consolidated snapshot
9.26.8.4. — Securing of Shingle Courses
(1) The first course of shingles shall be secured by a continuous band of cement along the eaves applied so that the width of the band equals the shingle exposure plus 100 mm.
(2) The succeeding courses of shingles shall be secured by a continuous band of cement applied so that the width of the band equals the shingle exposure plus 50 mm.
(3) The band required in Sentence (2) shall be located not more than 50 mm above the butt of the overlying course of shingles.
Text · e-Laws consolidated snapshot
9.26.8.5. — Hips and Ridges
(1) Shingles on hips and ridges shall be not less than 300 mm wide applied to provide triple coverage.
(2) Shingles referred to in Sentence (1) shall be cemented to the roof shingles and to each other with a coat of cement and fastened with nails or staples located 40 mm above the butt of the overlying shingle and 50 mm from each edge.
Text · e-Laws consolidated snapshot
9.26.8.6. — Flashing
(1) Flashing shall conform to Subsection 9.26.4.
Text · e-Laws consolidated snapshot
9.26.8.7. — Fastening
(1) Shingles shall be fastened in accordance with Article 9.26.7.4.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 9.26.8. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation