9.25.3.1. — Required Barrier to Air Leakage

(1) Thermally insulated wall, ceiling and floor assemblies shall be constructed so as to include an air barrier system that will provide a continuous barrier to air leakage,

(a) from the interior of the building into wall, floor, attic or roof spaces sufficient to prevent excessive moisture condensation in such spaces during the winter, and

(b) from the exterior inward sufficient to prevent moisture condensation on the room side during winter.