OBC 2006 › Division B
9.25.3.2.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.25.3.2.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
(7) Subsection 7 (3) and sections 134, 180, 224 to 230, 235 and 239 come into force on January 1, 2012.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(7)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.25.3.2.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
(7) Subsection 7 (3) and sections 134, 180, 224 to 230, 235 and 239 come into force on January 1, 2012.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(7)
Provenance
OBC 1997 · continues from 9.25.3.2. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 180 · ext v1 →
In force 2012-01-01
Next: O. Reg. 503/09, cl. 180 · ext (not in force until 2012-01-01) v1 →
OBC 2012 · continues as 9.25.3.2. — Pro
9.25.3.2. — Air Barrier System Properties
(1) Sheet and panel type materials intended to provide the principal resistance to air leakage shall have an air leakage characteristic not greater than 0.02 L/(s∙m2) measured at an air pressure differential of 75 Pa.
(2) Where polyethylene sheet used to provide the air-tightness in the air barrier system shall conform to CAN/CGSB-51.34-M, “Vapour Barrier, Polyethylene Sheet for Use in Building Construction”.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 9.25.3.2. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 180 · ext v1 →
In force 2012-01-01 compare
Next: O. Reg. 503/09, cl. 180 · ext (not in force until 2012-01-01) v1 →
OBC 2012 · continues as 9.25.3.2. — Pro