CodeChronicle

OBC 2006 Division B

9.21.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.21.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.21.1. — Pro

9.21.1. — General

Content not available for this version.

9.21.1.1. — Application

(1) This Section applies to,

(a) rectangular masonry or concrete chimneys not more than 12 m in height serving fireplaces or serving appliances having a combined total rated heat output of 120 kW or less, and

(b) flue pipes serving solid fuel-burning appliances.

(2) Chimneys and flue pipes other than those described in Sentence (1) shall conform to Section 6.3.

Text · e-Laws consolidated snapshot

9.21.1.2. — Factory-Built Chimneys

(1) Factory-built chimneys serving solid fuel-burning appliances, and their installation, shall conform to CAN/ULC-S629-M, “650°C Factory-Built Chimneys”.

Text · e-Laws consolidated snapshot

9.21.1.3. — Chimneys, Gas Vents or Flue Pipes

(1) Except as provided in Sentence (2), chimneys (other than those described in Sentences 9.21.1.1.(1) and 9.21.1.2.(1)), gas vents and flue pipes serving gas-, oil- or solid fuel-burning appliances and associated equipment shall conform to Section 6.3.

(2) Flue pipes serving solid fuel-burning stoves, ranges and space heaters shall conform to CAN/CSA-B365, “Installation Code for Solid-Fuel Burning Appliances and Equipment”.

Text · e-Laws consolidated snapshot

9.21.1.4. — Chimney or Flue Pipe Walls

(1) The walls of any chimney or flue pipe shall be constructed to be smoke- and flame-tight.

Text · e-Laws consolidated snapshot