CodeChronicle

OBC 2006 Division B

9.21.1.3.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.21.1.3. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · split into 9.21.1.1. — Pro

OBC 2012 · split into 9.21.1.3. — Pro

9.21.1.3. — Chimneys, Gas Vents or Flue Pipes

(1) Except as provided in Sentence (2), chimneys (other than those described in Sentences 9.21.1.1.(1) and 9.21.1.2.(1)), gas vents and flue pipes serving gas-, oil- or solid fuel-burning appliances and associated equipment shall conform to Section 6.3.

(2) Flue pipes serving solid fuel-burning stoves, ranges and space heaters shall conform to CAN/CSA-B365, “Installation Code for Solid-Fuel Burning Appliances and Equipment”.

Text · e-Laws consolidated snapshot