9.18.7. — Fire Protection

Content not available for this version.

9.18.7.1. — Crawl Spaces as Warm Air Plenums

(1) Only crawl spaces under 1-storey portions of dwelling units shall be used as warm-air plenums.

(2) Enclosing material in crawl spaces described in Sentence (1) including insulation shall have a surface flame-spread rating not greater than 150.

(3) Combustible ground cover used as enclosing material in Sentence (2) shall be covered with noncombustible material.