CodeChronicle

OBC 2006 Division B

9.10.14.4.

Version 1 — in force 1 January 2010

In force · amended
Verified · covered Verified against the 2010-01-01–2010-03-31 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 9.10.14.1. — Pro

OBC 1997 · merged from 9.10.14.10. — Pro

OBC 1997 · split from 9.10.14.14. — Pro

OBC 1997 · merged from 9.10.14.4. — Pro

OBC 1997 · merged from 9.10.14.5. — Pro

OBC 1997 · merged from 9.10.14.6. — Pro

OBC 1997 · merged from 9.10.14.9. — Pro

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 503/09, cl. 147(2) · ext ← current

In force 2010-01-01

OBC 2012 · continues as 9.10.14.4. — Pro

9.10.14.4. — Openings in Exposing Building Face

(1) Except as provided in Sentences (3) to (7) and Sentence 9.10.14.6.(1), the maximum aggregate area of unprotected openings in an exposing building face shall,

(a) conform to Table 9.10.14.4.,

(b) conform to Subsection 3.2.3., or

(c) be equal to or less than,

(i) the limiting distance squared, for residential occupancies, business and personal services occupancies and low hazard industrial occupancies, and

(ii) half the limiting distance squared, for mercantile occupancies and medium hazard industrial occupancies.

(2) Except as provided in Sentence 9.10.14.6.(1), openings in a wall having a limiting distance of less than 1.2 m shall be protected by closures, of other than wired glass or glass block, whose fire protection rating is in conformance with the fire-resistance rating required for the wall.

(3) The maximum aggregate area of unprotected openings shall be not more than twice the area determined according to Sentence (1) where the unprotected openings are glazed with,

(a) wired glass in steel frames as described in Article 9.10.13.5., or

(b) glass blocks, as described in Article 9.10.13.7.

(4) Where the building is sprinklered, the maximum aggregate area of unprotected openings shall be not more than twice the area determined according to Sentence (1) provided all rooms, including closets and bathrooms, that are adjacent to the exposing building face and that have unprotected openings are sprinklered, notwithstanding any exemptions in the sprinkler standards referenced in Article 3.2.5.13.

(5) The maximum aggregate area of unprotected openings in an exposing building face of a storage garage need not comply with Sentence (1) where,

(a) all storeys are constructed as open-air storeys, and

(b) the storage garage has a limiting distance of not less than 3 m.

(6) The maximum aggregate area of unprotected openings in an exposing building face of a storey that faces a street and is the same level as the street need not comply with Sentence (1) where the limiting distance is not less than 9 m.

(7) The limits on area of unprotected openings need not apply to the exposing building face of a detached garage or accessory building facing a dwelling unit, where,

(a) the detached garage or accessory building serves a single dwelling unit,

(b) the detached garage or accessory building is located on the same property as that dwelling unit, and

(c) the dwelling unit served by the detached garage or accessory building is the only major occupancy on the property.

Text · e-Laws consolidated snapshot

Table 9.10.14.4. Maximum Aggregate Area of Unprotected Openings in Exterior Walls Forming Part of Sentence 9.10.14.4.(1)

Column 1

Column 2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Occupancy Classification of Building

Maximum Total Area of Exposing Building Face, m²

Maximum Aggregate Area of Unprotected Openings, % of Exposing Building Face Area

Limiting Distance, m

Less than 1.2

1.2

1.5

2

2.5

3

4

6

8

10

12

16

20

25

Residential, business and personal services and low-hazard industrial

10

0

8

12

21

33

55

96

100

15

0

8

10

17

25

37

67

100

20

0

8

10

15

21

30

53

100

25

0

8

9

13

19

26

45

100

30

0

7

9

12

17

23

39

88

100

40

0

7

8

11

15

20

32

69

100

50

0

7

8

10

14

18

28

57

100

100

0

7

8

9

11

13

18

34

56

84

100

Over 100

0

7

7

8

9

10

12

19

28

40

55

92

100

Mercantile and medium-hazard industrial

10

0

4

6

10

17

25

48

100

15

0

4

5

8

13

18

34

82

100

20

0

4

5

7

11

15

27

63

100

25

0

4

5

7

9

13

22

51

94

100

30

0

4

4

6

9

12

20

44

80

100

40

0

4

4

6

8

10

16

34

61

97

100

50

0

4

4

5

7

9

14

29

50

79

100

100

0

4

4

4

5

6

9

17

28

42

60

100

Over 100

0

4

4

4

4

5

6

10

14

20

27

46

70

100