(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.10.14.5.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · renumbered from 9.10.14.11. — Pro
OBC 1997 · merged from 9.10.14.13. — Pro
OBC 1997 · split from 9.10.14.14. — Pro
OBC 1997 · merged from 9.10.14.15. — Pro
OBC 1997 · merged from 9.10.14.16. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.10.14.5. — Pro
9.10.14.5. — Construction of Exposing Building Face and Walls above Exposing Building Face
(1) Except as permitted in Sentences (2) to (7), each exposing building face and any exterior wall located above an exposing building face that encloses an attic or roof space shall be constructed in conformance with Table 9.10.14.5. and Subsection 9.10.8.
(2) Cladding on exposing building faces and exterior walls located above exposing building faces need not conform to the type of cladding required by Table 9.10.14.5. where,
(a) the exposing building face is constructed with no unprotected openings,
(b) the limiting distance is not less than 0.6 m, and
(c) the cladding,
(i) conforms to Subsection 9.27.13.,
(ii) is installed without furring members over not less than 12.7 mm thick gypsum sheathing or over masonry,
(iii) has a flame-spread rating not more than 25 when tested in accordance with Sentence 3.1.12.1.(2), and
(iv) is not more than 2 mm in thickness exclusive of fasteners, joints and local reinforcements.
(3) Except as provided in Sentence (4), where a garage or accessory building serves a single dwelling unit and is detached from any building, the exposing building face,
(a) need not conform to the minimum required fire-resistance rating in Table 9.10.14.5., where the limiting distance is 0.6 m or more,
(b) shall have a fire-resistance rating of not less than 45 min where the limiting distance is less than 0.6 m, and
(c) need not conform to the type of cladding required in Table 9.10.14.5. regardless of the limiting distance.
(4) The requirements for fire-resistance rating, type of construction and type of cladding need not apply to the exposing building faces of a dwelling unit and a detached garage or accessory building that face each other, where,
(a) the detached garage or accessory building serves a single dwelling unit,
(b) the detached garage or accessory building is located on the same property as that dwelling unit, and
(c) the dwelling unit served by the detached garage or accessory building is the only major occupancy on the property.
(5) Except for buildings containing 1 or 2 dwelling units only, combustible projections on the exterior of a wall that are more than 1 000 mm above ground level, such as balconies, platforms, canopies, eave projections and stairs, and that could expose an adjacent building to fire spread, shall not be permitted within,
(a) 1.2 m of a property line or the centre line of a public way, or
(b) 2.4 m of a combustible projection on another building on the same property.
(6) Heavy timber and steel columns need not conform to the requirements of Sentence (1) provided the limiting distance is not less than 3 m.
(7) Non-loadbearing wall components need not have a minimum fire-resistance rating where,
(a) the building is 1 storey in building height,
(b) the building is of noncombustible construction,
(c) the building is classified as low hazard industrial occupancy and is used only for low fire load occupancies such as power generating plants or plants for the manufacture or storage of noncombustible materials, and
(d) the exposing building face has a limiting distance of 3 m or more.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 | Column 4 | Column 5 |
Occupancy Classification of Building | Maximum Area of Unprotected Openings Permitted, % of Exposing Building Face Area | Minimum Required Fire-Resistance Rating | Type of Construction Required | Type of Cladding Required |
Residential, business and personal services, and low-hazard industrial | 0 - 10 | 1 h | Noncombustible | Noncombustible |
>10 but ≤25 | 1 h | Combustible or noncombustible | Noncombustible | |
>25 but <100 | 45 min | Combustible or noncombustible | Combustible or noncombustible | |
Mercantile and medium-hazard industrial | 0 - 10 | 2 h | Noncombustible | Noncombustible |
>10 but ≤25 | 2 h | Combustible or noncombustible | Noncombustible | |
>25 but <100 | 1 h | Combustible or noncombustible | Combustible or noncombustible |
Provenance
OBC 1997 · renumbered from 9.10.14.11. — Pro
OBC 1997 · merged from 9.10.14.13. — Pro
OBC 1997 · split from 9.10.14.14. — Pro
OBC 1997 · merged from 9.10.14.15. — Pro
OBC 1997 · merged from 9.10.14.16. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.10.14.5. — Pro