CodeChronicle

OBC 2006 Division B

8.2.1.5.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 8.2.1.5. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 8.2.1.5. — Pro

8.2.1.5. — Clearance Distances for Class 1, 2 and 3 Sewage Systems

(1) Except as provided in Sentences 8.2.1.4.(1) and (2), no Class 1, 2, or 3 sewage system shall have a horizontal distance of less than that permitted by Table 8.2.1.5.

Editor's note

This map follows the as-filed text of O. Reg. 350/06 for Article 8.2.1.5. of Division B, in which Sentence (1) reads 'no Class 1, 2, or 3 sewage system' with a serial comma before 'or'. The e-Laws consolidation editorially drops the serial comma, rendering 'Class 1, 2 or 3', with no amending regulation making the change. This map preserves the as-filed wording.

Text · e-Laws consolidated snapshot

Table 8.2.1.5. Clearance Distances for Class 1, 2 and 3 Sewage Systems Forming Part of Sentence 8.2.1.5.(1)

Column 1

Column 2

Column 3

Column 4

Column 5

Sewage System

Minimum horizontal distance in metres from a well with watertight casing to a depth of at least 6 m

Minimum horizontal distance in metres from a spring used as a source of potable water or well other than a well with a water tight casing to a depth of at least 6 m

Minimum horizontal distance in metres from a lake, river, pond, stream, reservoir, or a spring not used as a source of potable water

Minimum horizontal distance in metres from a property line

Earth Pit Privy

15

30

15

3

Privy Vault

Pail Privy

10

15

10

3

Greywater System

10

15

15

3

Cesspool

30

60

15

3