CodeChronicle

OBC 2006 Division B

7.2.7.4.

Version 1 — in force 2 April 2007

In force · amended
Verified · covered Verified against the 2007-04-02–2007-06-30 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 7.2.7.4. — Pro

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 137/07, cl. 36 · ext ← current

In force 2007-04-02

O. Reg. 503/09, cl. 92 · ext v2 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 92 · ext (not in force until 2010-01-01) v2 →

OBC 2012 · continues as 7.2.7.4. — Pro

7.2.7.4. — Copper Tube

Comparing versions

Changed text stands out · unchanged is dimmed

v0 base

Earlier · 2006-12-31

(1) Copper tube in a plumbing system shall,

(a) be certified to ASTM B88, “Seamless Copper Water Tube”, or

(b) comply with ASTM B306, “Copper Drainage Tube (DWV)”.

(2) The use of copper tube shall conform to Table 7.2.7.4.

(3) Copper tube used in a plumbing appliance shall conform to,

(a) ASTM B88, “Seamless Copper Water Tube”, or

(b) ASTM B68, “Seamless Copper Tube”.

(4) Type K or L copper tube shall be used for the potable water side of a heat exchanger in a pre-engineered wastewater heat recovery system.

v1 O. Reg. 137/07

Later · viewing · 2007-04-02

(1) Copper tube in a plumbing system shall,

(a) be certified to ASTM B88, “Seamless Copper Water Tube”, or

(b) comply with ASTM B306, “Copper Drainage Tube (DWV)”.

(2) The use of copper tube shall conform to Table 7.2.7.4.

(3) Copper tube used in a plumbing appliance shall conform to,

(a) ASTM B88, “Seamless Copper Water Tube”, or

(b) ASTM B68, “Seamless Copper Tube”.

(4) Type K or L copper tube shall be used for the potable water side of a heat exchanger in a pre-engineered wastewater heat recovery system.