7.2.7.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 7.2.7. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 7.2.7. — Pro

7.2.7. — Non-Ferrous Pipe and Fittings

Content not available for this version.

7.2.7.1. — Copper and Brass Pipe

(1) Copper pipe shall conform to ASTM B42, “Seamless Copper Pipe, Standard Sizes”.

(2) Brass pipe shall conform to ASTM B43, “Seamless Red Brass Pipe, Standard Sizes”.

Text · e-Laws consolidated snapshot

7.2.7.2. — Brass or Bronze Pipe Flanges and Flanged Fittings

(1) Brass or bronze pipe flanges and flanged fittings shall conform to ANSI/ASME B16.24, “Cast Copper Alloy Pipe Flanges and Flanged Fittings”.

Text · e-Laws consolidated snapshot

7.2.7.3. — Brass or Bronze Threaded Water Fittings

(1) Brass or bronze threaded water fittings shall conform to ANSI/ASME B16.15, “Cast Bronze Threaded Fittings, Classes 125 and 250”.

(2) Brass or bronze threaded water fittings shall not be used in a drainage system.

Text · e-Laws consolidated snapshot

7.2.7.4. — Copper Tube

(1) Copper tube in a plumbing system shall,

(a) be certified to ASTM B88, “Seamless Copper Water Tube”, or

(b) comply with ASTM B306, “Copper Drainage Tube (DWV)”.

(2) The use of copper tube shall conform to Table 7.2.7.4.

(3) Copper tube used in a plumbing appliance shall conform to,

(a) ASTM B88, “Seamless Copper Water Tube”, or

(b) ASTM B68, “Seamless Copper Tube”.

(4) Type K or L copper tube shall be used for the potable water side of a heat exchanger in a pre-engineered wastewater heat recovery system.

Editor's note

In the notes to Table 7.2.7.4., the 'Not Permitted' legend is filed in O. Reg. 350/06 with a space before the dash ('NP – Not Permitted') and the notes heading appears in bold; this map reproduces the source as filed. The e-Laws consolidation closes that spacing ('NP–') and renders the heading in regular weight. These formatting differences were not enacted by an amending regulation.

Text · e-Laws consolidated snapshot

Table 7.2.7.4. Permitted Use of Copper Tube and Pipe Forming Part of Sentence 7.2.7.4.(2)

Column 1

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Column 8

Type of Copper Tube or Pipe

Water Distribution System

Building Sewer

Drainage System

Venting System

Under ground

Above ground

Under ground

Above ground

Under ground

Above ground

K & L hard

N

P

P

P

P

P

P

K & L soft

P

P

N

N

N

N

N

M hard

N

P

N

N

P

N

P

M soft

N

N

N

N

N

N

N

DWV

N

N

N

N

P

N

P

Notes to Table 7.2.7.4.:

P  – Permitted

NP – Not Permitted

7.2.7.5. — Solder-Joint Drainage Fittings

(1) Solder-joint fittings for drainage systems shall conform to,

(a) ASME B16.23, “Cast Copper Alloy Solder Joint Drainage Fittings: DWV”, or

(b) ANSI/ASME B16.29, “Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings – DWV”.

(2) Solder-joint fittings for drainage systems shall not be used in a water system.

Text · e-Laws consolidated snapshot

7.2.7.6. — Solder-Joint Water Fittings

(1) Except as provided in Sentence (2), solder-joint fittings for water systems shall conform to,

(a) ANSI B16.18, “Cast Copper Alloy Solder Joint Pressure Fittings”, or

(b) ANSI/ASME B16.22, “Wrought Copper and Copper Alloy Solder Joint Pressure Fittings”.

(2) Solder-joint fittings for water systems not made by casting or the wrought process shall conform to the applicable requirements of ANSI B16.18, “Cast Copper Alloy Solder Joint Pressure Fittings”.

Text · e-Laws consolidated snapshot

7.2.7.7. — Flared-Joint Fittings for Copper Water Systems

(1) Flared-joint fittings for copper tube water systems shall conform to ANSI/ASME B16.26, “Cast Copper Alloy Fittings for Flared Copper Tubes”.

(2) Flared-joint fittings for copper tube water systems not made by casting shall conform to the applicable requirements of ANSI/ASME B16.26, “Cast Copper Alloy Fittings for Flared Copper Tubes”.

Text · e-Laws consolidated snapshot

7.2.7.8. — Lead Waste Pipe and Fittings

(1) Lead waste pipe and fittings shall not be used in a water system or for a building sewer.

(2) When there is a change in size of a lead closet bend, the change shall be in the vertical section of the bend or made in such a manner that there shall be no retention of liquid in the bend.

Text · e-Laws consolidated snapshot