CodeChronicle

OBC 2006 Division B

7.2.5.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 7.2.5. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 7.2.5. — Pro

7.2.5. — Non-Metallic Pipe and Fittings

Content not available for this version.

7.2.5.1. — Asbestos-Cement Drainage Pipe and Fittings

(1) Except as provided in Sentence (2), asbestos-cement pipe and its fittings for use in a drain, waste or vent system shall conform to,

(a) CAN/CGSB-34.22, “Asbestos-Cement Drain Pipe”, or

(b) CSA B127.1, “Asbestos Cement Drain, Waste and Vent Fittings”.

(2) Asbestos-cement pipe and fittings used underground either outside a building or under a building shall conform to Sentence (1) or to,

(a) CAN/CGSB-34.9, “Asbestos-Cement Sewer Pipe”,

(b) CAN/CGSB-34.23, “Asbestos-Cement House Connection Sewer Pipe”, or

(c) CSA B127.2, “Components for Use in Asbestos-Cement Building Sewer Systems”.

Text · e-Laws consolidated snapshot

7.2.5.2. — Reserved.

Content not available for this version.

Editor's note

As filed in O. Reg. 350/06, the heading of this article reads 'Reserved.' with a closing period. The consolidated e-Laws text renders it without the period ('Reserved'); the as-filed heading is retained here.

7.2.5.3. — Concrete Pipe and Fittings

(1) Concrete pipe shall conform to CSA A257 Series, “Standards for Circular Concrete Pipe and Manholes”.

(2) Joints with external elastomeric gaskets shall be made with corrosion resistant external band type flexible mechanical couplings that conform to CAN/CSA-B602, “Mechanical Couplings for Drain, Waste, and Vent Pipe and Sewer Pipe”.

(3) Concrete fittings field fabricated from lengths of pipe shall not be used.

(4) Concrete pipe shall not be used above ground inside a building.

(5) Precast reinforced circular concrete manhole sections, catch basins and fittings shall conform to CSA A257.4, “Precast Reinforced Circular Concrete Manhole Sections, Catch Basins, and Fittings”.

Text · e-Laws consolidated snapshot

7.2.5.4. — Vitrified Clay Pipe and Fittings

(1) Vitrified clay pipe and fittings shall be certified to CSA A60.1-M, “Vitrified Clay Pipe”.

(2) Couplings and joints for vitrified clay pipe shall be certified to CSA A60.3-M, “Vitrified Clay Pipe Joints”.

(3) Vitrified clay pipe and fittings shall not be used except for an underground part of a drainage system.

Text · e-Laws consolidated snapshot

7.2.5.5. — Polyethylene Pipe and Fittings

(1) Polyethylene water pipe, tubing and fittings shall be certified to Series 160 of CAN/CSA-B137.1, “Polyethylene Pipe, Tubing and Fittings for Cold Water Pressure Services”.

(2) Except as permitted in Sentence 7.2.5.7.(1)v1, polyethylene water pipe shall not be used except for a water service pipe.

(3) Butt fusion fittings for polyethylene pipe shall conform to ASTM D3261, “Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing”.

Text · e-Laws consolidated snapshot

7.2.5.6. — Polyethylene Pipe Used Underground

(1) Polyethylene pipe used underground in a drainage system for rehabilitation of existing systems using trenchless technology shall conform to ASTM F714, “Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter” and shall be HDPE 3408, SDR 17 or heavier.

Text · e-Laws consolidated snapshot

7.2.5.7. — Crosslinked Polyethylene Pipe and Fittings

(1) Cross-linked polyethylene pipe and its associated fittings used in hot and cold potable water systems shall be certified to CAN/CSA-B137.5, “Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications”.

Text · e-Laws consolidated snapshot

7.2.5.8. — PVC Pipe and Fittings

(1) PVC water pipe, fittings and solvent cement shall be certified to CAN/CSA-B137.3, “Rigid Polyvinyl Chloride (PVC) Pipe for Pressure Applications” or CAN/CSA-B137.2, “PVC Injection-Moulded Gasketed Fittings for Pressure Applications”, and have a minimum pressure rating of 1 100 kPa.

(2) PVC water pipe and fittings in Sentence (1) shall not be used in a hot water system.

Text · e-Laws consolidated snapshot

7.2.5.9. — CPVC Pipe, Fittings and Solvent Cements

(1) CPVC hot and cold water pipe, fittings and solvent cements shall be certified to CSA B137.6, “CPVC Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems”.

(2) The design temperature and design pressure of a CPVC piping system shall conform to CSA B137.6, “CPVC Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems”.

Text · e-Laws consolidated snapshot

7.2.5.10. — Plastic Pipe, Fittings and Solvent Cement Used Underground

(1) Plastic pipe, fittings and solvent cement used underground outside a building or under a building in a drainage system shall be certified to,

(a) ASTM F628, “Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste and Vent Pipe With a Cellular Core”.

(b) CAN/CSA-B181.1, “ABS Drain, Waste, and Vent Pipe and Pipe Fittings”,

(c) CAN/CSA-B181.2, “PVC Drain, Waste, and Vent Pipe and Pipe Fittings”,

(d) CAN/CSA-B182.1, “Plastic Drain and Sewer Pipe and Pipe Fittings”,

(e) CAN/CSA-B182.2, “PVC Sewer Pipe and Fittings, (PSM Type)”,

(f) CAN/CSA-B182.4, “Profile (Ribbed) PVC Sewer Pipe and Fittings”,

(g) CAN/CSA-B182.6, “Profile Polyethylene Sewer Pipe and Fittings”,

(h) CAN/CSA B182.7, “Multilayer PVC Sewer Pipe (PSM Type) Having Reprocessed-Recycled Content”,

(i) CAN/CSA-B137.2, “PVC Injection-Moulded Gasketed Fittings for Pressure Applications”, or

(j) CAN/CSA-B137.3, “Rigid Polyvinyl Chloride (PVC) Pipe for Pressure Applications”,

(2) Except as permitted in Clauses (i) and (j), plastic pipe used as described in Sentence (1) shall have a stiffness equal or greater than 320 kPa.

Text · e-Laws consolidated snapshot

7.2.5.11. — Transition Solvent Cement

(1) Solvent cement for transition joints shall conform to,

(a) CAN/CSA-B181.1, “ABS Drain, Waste and Vent Pipe and Pipe Fittings”, or

(b) CAN/CSA-B181.2, “PVC Drain, Waste and Vent Pipe and Pipe Fittings”.

(2) Transition solvent cement shall only be used for joining an ABS plumbing system to a PVC plumbing system.

Text · e-Laws consolidated snapshot

7.2.5.12. — Plastic Pipe, Fittings and Solvent Cement Used in Buildings

(1) Plastic pipe, fittings and solvent cement used inside or under a building in a sanitary drainage system or venting system shall be certified to,

(a) ASTM F628, “Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe With a Cellular Core”.

(b) CAN/CSA-B181.1, “ABS Drain, Waste, and Vent Pipe and Pipe Fittings”, or

(c) CAN/CSA-B181.2, “PVC Drain, Waste, and Vent Pipe and Pipe Fittings”.

(2) Plastic pipe, fittings and solvent cement used inside a building in a storm drainage system shall be certified to,

(a) ASTM F628, “Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe With a Cellular Core”.

(b) CAN/CSA-B181.1, “ABS Drain, Waste, and Vent Pipe and Pipe Fittings”,

(c) CAN/CSA-B181.2, “PVC Drain, Waste, and Vent Pipe and Pipe Fittings”,

(d) CAN/CSA-B182.1, “Plastic Drain and Sewer Pipe and Pipe Fittings”, or

(e) CAN/CSA-B182.2, “PVC Sewer Pipe and Fittings, (PSM Type)”.

(3) Plastic pipe used as described in Sentence (2) shall have a pipe stiffness equal or greater than 320 kPa.

(4) Requirements for combustible piping in relation to fire safety shall conform to Sentences 3.1.5.16.(1) and 9.10.9.6.(2) to (8) and Articles 3.1.9.4. and 9.10.9.7.

(5) Where noncombustible piping pierces a fire separation or a fire stop, the requirements for fire stopping of Subsection 3.1.9., Sentence 9.10.9.6.(1) and Article 9.10.16.4. shall apply.

Text · e-Laws consolidated snapshot

7.2.5.13. — Polyethylene/Aluminum/Polyethylene Composite Pipe and Fittings

(1) PE/AL/PE composite pipe and fittings used for potable water systems shall conform to CAN/CSA-B137.9, “Polyethylene/Aluminum/ Polyethylene Composite Pressure Pipe Systems”.

(2) PE/AL/PE pipe and fittings shall not be used in a hot water system.

Text · e-Laws consolidated snapshot

7.2.5.14. — Crosslinked Polyethylene/ Aluminum/ Polyethylene Composite Pipe and Fittings

(1) PEX/AL/PEX composite pipe and fittings used for potable water systems shall conform to CAN/CSA-B137.10, “Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe Systems”.

Text · e-Laws consolidated snapshot

7.2.5.15. — Polypropylene Pipe and Fittings

(1) Polypropylene pipe and fittings used for hot and cold potable water systems shall conform to CAN/CSA-B137.11, “Polypropylene (PP-R) Pipe and Fittings for Pressure Applications”.

Text · e-Laws consolidated snapshot