CodeChronicle

OBC 2006 Division B

7.2.5.8.

Version 1 — in force 1 January 2010

In force · amended
Verified · covered Verified against the 2010-01-01–2010-03-31 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 7.2.5.6. — Pro

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 503/09, cl. 82 · ext ← current

In force 2010-01-01

OBC 2012 · continues as 7.2.5.8. — Pro

7.2.5.8. — PVC Pipe and Fittings

(1) PVC water pipe, fittings and solvent cement shall be certified to CAN/CSA-B137.3, “Rigid Polyvinylchloride (PVC) Pipe for Pressure Applications” or CAN/CSA-B137.2, “Polyvinylchloride (PVC) Injection-Moulded Gasketed Fittings for Pressure Applications”, and have a minimum pressure rating of 1 100 kPa.

(2) PVC water pipe and fittings in Sentence (1) shall not be used in a hot water system.

Text · e-Laws consolidated snapshot