7.2.3. — Traps and Interceptors

Content not available for this version.

7.2.3.1. — Traps

(1) Except as provided for in Sentence (2), every trap shall,

(a) have a trap seal depth of at least 38 mm,

(b) be so designed that failure of the seal walls will cause exterior leakage, and

(c) have a water seal that does not depend on the action of moving parts.

(2) The trap seal depth on fixtures draining to an acid waste system shall be a minimum of 50 mm.

(3) Every trap that serves a lavatory, a sink or a laundry tray shall,

(a) be provided with a cleanout plug of a minimum ¾ in. size located at the lowest point of the trap and of the same material as the trap, except that a cast iron trap shall be provided with a brass cleanout plug, or

(b) be designed so that part of the trap can be removed for cleaning purposes.

(4) A bell trap or an S-trap shall not be installed in a drainage system.

(5) A drum trap shall not be installed in a drainage system.

(6) Except as permitted in Sentence (7), no bottle trap shall be used in a plumbing system.

(7) A bottle trap may be used on a laboratory sink or other fixture equipped with corrosion resistant fittings.

(8) No running trap shall be installed in a plumbing system unless an accessible handhole is provided for cleaning of the trap, and where the trap is too small to accommodate a handhole, a cleanout shall be provided.

Text · e-Laws consolidated snapshot

7.2.3.2. — Interceptors

(1) Every interceptor shall be designed so that it can be readily cleaned.

(2) Every grease interceptor shall be designed so that it does not become air bound.

Text · e-Laws consolidated snapshot

7.2.3.3. — Tubular Traps

(1) Tubular metal or plastic traps that conform to CAN/CSA-B125, “Plumbing Fittings” shall be used in accessible locations.

Text · e-Laws consolidated snapshot