(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 5.6.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 5.6. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 5.6. — Pro
5.6. — Precipitation
Content not available for this version.
5.6.1. — Protection from Precipitation
Content not available for this version.
5.6.1.1. — Required Protection from Precipitation
(1) Except as provided in Sentence (2), where a building component or assembly is exposed to precipitation, the component or assembly shall,
(a) minimize ingress of precipitation into the component or assembly, and
(b) prevent ingress of precipitation into interior space.
(2) Protection from ingress of precipitation is not required where it can be shown that such ingress will not adversely affect any of,
(a) the health or safety of building users,
(b) the intended use of the building, or
(c) the operation of building services.
Text · e-Laws consolidated snapshot
5.6.1.2. — Protective Material and Component Properties
(1) Except as provided in Sentence (2), where western cedar shakes or shingles are installed to provide the required protection from precipitation,
(a) shakes shall be not less than No.1 or Handsplit grade, and
(b) shingles shall be not less than No. 2 grade.
(2) Where western cedar shakes or shingles are installed as undercoursing to provide required protection from precipitation on vertical assemblies, they shall be not less than No. 3 grade.
(3) Except as provided in Sentence (4), where eastern white cedar shingles are installed to provide the required protection from precipitation, they shall be not less less than B (clear) grade.
(4) Where eastern white shingles are installed as undercoursing to provide the required protection from precipitation on vertical assemblies, they shall be not less than C grade.
Text · e-Laws consolidated snapshot
5.6.1.3. — Installation of Protective Materials
(1) Where a material applied to a sloped or horizontal assembly is installed to provide required protection from precipitation and its installation is covered in the scope of one of the following standards, installation shall conform to the requirements of the respective standard:
(a) CAN/CGSB-37.51-M, “Application of Hot Applied Rubberized Asphalt for Roofing and Waterproofing”,
(b) CGSB 37-GP-55M, “Application of Sheet Applied Flexible Polyvinyl Chloride Roofing Membrane”,
(c) CAN3-A123.51-M, “Asphalt Shingle Application on Roof Slopes 1:3 and Steeper”, or
(d) CAN3-A123.52-M, “Asphalt Shingle Application on Roof Slopes 1:6 to less than 1:3”.
(2) Where masonry applied to vertical assemblies is installed to provide required protection from precipitation, installation shall conform to the requirements of CSA A371, “Masonry Construction for Buildings”.
(3) Where protective materials are applied to assemblies to provide the required protection from precipitation, the materials shall be installed so as to shed precipitation or otherwise minimize its entry into the assembly and prevent its penetration through the assembly.
Text · e-Laws consolidated snapshot
5.6.2. — Sealing, Drainage, Accumulation and Disposal
Content not available for this version.
5.6.2.1. — Sealing and Drainage
(1) Except as provided in Sentence (2), materials, components, assemblies, joints in materials, junctions between components and junctions between assemblies exposed to precipitation shall be,
(a) sealed to prevent ingress of precipitation, or
(b) drained to direct precipitation to the exterior.
(2) Sealing or drainage are not required where it can be shown that the omission of sealing and drainage will not adversely affect any of,
(a) the health or safety of building users,
(b) the intended use of the building, or
(c) the operation of building services.
Text · e-Laws consolidated snapshot
5.6.2.2. — Accumulation and Disposal
(1) Where water, snow or ice can accumulate on a building, provision shall be made to minimize the likelihood of hazardous conditions arising from such accumulation.
(2) Where precipitation can accumulate on sloped or horizontal assemblies, provision shall be made for drainage conforming with Section 7.4.
(3) Where downspouts are provided and are not connected to a sewer, provisions shall be made to,
(a) divert the water from the building, and
(b) prevent soil erosion.
(4) Junctions between vertical assemblies, and sloped or horizontal assemblies, shall be designed and constructed to minimize the flow of water from the sloped or horizontal assembly onto the vertical assembly.
Text · e-Laws consolidated snapshot
5.6.2.3. — Solar Collector Systems
(1) A solar collector system is permitted to be installed above roofing materials conforming to Table 5.10.1.1.v1
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 5.6. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 5.6. — Pro