CodeChronicle

OBC 2006 Division A

1.1.2.2.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 2.1.1.2. — Pro

OBC 1997 · split from 2.1.2.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

O. Reg. 503/09, cl. 1(2) · ext v1 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 1(2) · ext (not in force until 2010-01-01) v1 →

OBC 2012 · continues as 1.1.2.2. — Pro

1.1.2.2. — Application of Parts 3, 4, 5 and 6

Comparing versions

Changed text stands out · unchanged is dimmed

v0 base

Earlier · viewing · 2006-12-31

(1) Subject to Articles 1.1.2.6. and 1.3.1.2., Parts 3, 5 and 6 of Division B apply to all buildings,

(a) used for major occupancies classified as,

(i) Group A, assembly occupancies,

(ii) Group B, care or detention occupancies,

(iii) Group F, Division 1, high hazard industrial occupancies, or

(b) exceeding 600 m2 in building area or exceeding three storeys in building height and used for major occupancies classified as,

(i) Group C, residential occupancies,

(ii) Group D, business and personal services occupancies,

(iii) Group E, mercantile occupancies, or

(iv) Group F, Divisions 2 and 3, medium and low hazard industrial occupancies.

(2) Subject to Articles 1.1.2.6. and 1.3.1.2., Part 4 of Division B applies to,

(a) post-disaster buildings,

(b) buildings described in Sentence (1), and

(c) structures designated in Sentence 1.3.1.1.(1).

(3) Section 3.11. of Division B applies to public pools.

(4) Section 3.12. of Division B applies to public spas.

(5) Section 3.15. of Division B applies to signs.

v1 O. Reg. 503/09

Later · 2010-01-01

(1) Subject to Articles 1.1.2.6. and 1.3.1.2., Parts 3, 5 and 6 of Division B apply to all buildings,

(a) used for major occupancies classified as,

(i) Group A, assembly occupancies,

(ii) Group B, care or detention occupancies,

(iii) Group F, Division 1, high hazard industrial occupancies, or

(b) exceeding 600 m2 in building area or exceeding three storeys in building height and used for major occupancies classified as,

(i) Group C, residential occupancies,

(ii) Group D, business and personal services occupancies,

(iii) Group E, mercantile occupancies, or

(iv) Group F, Divisions 2 and 3, medium hazard industrial occupancies and low hazard industrial occupancies.

(2) Subject to Articles 1.1.2.6. and 1.3.1.2., Part 4 of Division B applies to,

(a) post-disaster buildings,

(b) buildings described in Sentence (1),

(c) a retaining wall exceeding 1 000 mm in exposed height adjacent to,

(i) public property,

(ii) access to a building, or

(iii) private property to which the public is admitted,

(d) a pedestrian bridge appurtenant to a building,

(e) a crane runway,

(f) an exterior storage tank and its supporting structure that is not regulated by the Technical Standards and Safety Act, 2000,

(g) signs regulated by Section 3.15. of Division B that are not structurally supported by a building,

(h) a structure that supports a wind turbine generator having a rated output of more than 3 kW,

(i) a communication tower exceeding 16.6 m above ground level, and

(j) an outdoor pool that has a water depth greater than 3.5 m at any point.

(3) Section 3.11. of Division B applies to public pools.

(4) Section 3.12. of Division B applies to public spas.

(5) Section 3.15. of Division B applies to signs.