CodeChronicle

OBC 2006 Division B

4.4.4.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 4.1.10.8. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

O. Reg. 503/09, cl. 67 · ext v1 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 67 · ext (not in force until 2010-01-01) v1 →

OBC 2012 · continues as 4.4.4.1. — Pro

4.4.4.1. — Anchor Systems on Building Exterior

(1) Where maintenance and window cleaning operations are intended to be carried out on the exterior of a building described in Article 1.3.2.2.v1 of Division A, anchor systems shall be provided where any portion of the roof is more than 8 m above adjacent ground level.

(2) Except as provided in Sentence (3), the anchor systems in Sentence (1) shall be designed, installed and tested in conformance with CSA Standard Z91, “ Safety Code for Window Cleaning Operations”.

(3) Other anchor systems may be used where such systems provide an equal level of safety.

(4) The anchor system material shall be made of stainless steel, or other corrosion resistant base material, or from steel that is hot dipped galvanised, in accordance with CAN/CSA-G164-M, “Hot Dip Galvanising of Irregularly Shaped Articles”.

Editor's note

In Sentence 4.4.4.1.(2), the title of CSA Standard Z91 is filed in O. Reg. 350/06 with a space after the opening quotation mark (“ Safety Code for Window Cleaning Operations”); this map reproduces the source as filed. The e-Laws consolidation removes that space. This punctuation difference was not enacted by an amending regulation.