OBC 2006 › Division B
4.1.5.3.
Version 1 — in force 2 April 2007
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 4.1.5.3.
- Version
- v1
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 4.1.5.3.
- Version
- v1
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · renumbered from 4.1.6.3. — Pro
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 137/07, cl. 30 · ext ← current
In force 2007-04-02
OBC 2012 · continues as 4.1.5.3. — Pro
4.1.5.3. — Full and Partial Loading
(1) The uniformly distributed live load shall be not less than the value listed in Table 4.1.5.3., which may be reduced as provided in Article 4.1.5.9., applied uniformly over the entire area, or on any portions of the area, whichever produces the most critical effects in the members concerned.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 |
Use of Area of Floor or Roof | Minimum Specified Load, kPa |
Assembly Areas | |
(a) Except for those areas listed under (b) and (c), assembly areas with or without fixed seats including | 4.8 |
Arenas | |
Auditoria | |
Churches and similar places of worship | |
Dance floors | |
Dining areas (1) | |
Foyers and entrance halls | |
Grandstands, reviewing stands and bleachers | |
Gymnasia | |
Museums | |
Promenades | |
Rinks | |
Stadia | |
Stages | |
Theatres | |
Other areas with similar uses | |
(b) Assembly areas with fixed seats that have backs over at least 80 per cent of the assembly area for the following uses: | 2.4 |
Churches and similar places of worship | |
Courtrooms | |
Lecture halls | |
Theatres | |
(c) Classrooms with or without fixed seats | 2.4 |
Attics | |
Accessible by a stairway in residential occupancies only | 1.4 |
Having limited accessibility so that there is no storage of equipment or materials | 0.5 |
Balconies | |
Exterior | 4.8 |
Interior and mezzanines that could be used for the assembly of people as a viewing area (2) | 4.8 |
Interior and mezzanines other than above | (2) |
Corridors, lobbies and aisles | |
Other than those listed below | 4.8 |
Not over 1 200 mm in width and all upper floor corridors of residential areas only of apartments, hotels and motels (that can not be used for the assembly of people as viewing area) (2) | (2) |
In a Group B, Division 3 occupancy that contains sleeping accommodation for not more than 10 persons and not more than 6 occupants require assistance in evacuation in case of an emergency. | 2.4 |
Equipment areas and service rooms including | 3.6(3) |
Generator rooms | |
Mechanical equipment exclusive of elevators | |
Machine rooms | |
Pump rooms | |
Transformer vaults | |
Ventilating or air-conditioning equipment | |
Exits and fire escapes | 4.8 |
Factories | 6.0(3) |
Footbridges | 4.8 |
Garages for | |
Passenger cars | 2.4 |
Unloaded buses and light trucks | 6.0 |
Loaded buses and trucks and all other trucking spaces | 12.0 |
Kitchens (other than residential) | 4.8 |
Libraries | |
Stack rooms | 7.2 |
Reading and study rooms | 2.9 |
Office areas (not including record storage and computer rooms) located in | |
Basement and first storey | 4.8 |
Floors above first storey | 2.4 |
Operating rooms and laboratories | 3.6 |
Patients' bedrooms | 1.9 |
Recreation areas that cannot be used for assembly purposes including | 3.6 |
Billiard rooms | |
Bowling alleys | |
Pool rooms | |
Residential areas (within the scope of Article 1.3.3.2 of Division A) | |
Sleeping and living quarters in apartments, hotels, motels, boarding schools and colleges | 1.9 |
Work areas within live/work units | 2.4 |
Residential areas (within the scope of Article 1.3.3.3 of Division A) | |
Bedrooms | 1.4 |
Other areas | 1.9 |
Stairs within dwelling units | 1.9 |
Retail and wholesale areas | 4.8 |
Roofs | 1.0(4) |
Sidewalks and driveways over areaways and basements | 12.0 |
Storage areas, including locker rooms in apartment buildings | 4.8(3) |
Toilet areas | 2.4 |
Underground slabs with earth cover | (5) |
Warehouses | 4.8(3) |
Notes to Table 4.1.5.3.:
(1)See Article 4.1.5.6.
(2)See Article 4.1.5.4.
(3)See Article 4.1.5.7.
(4)See Article 4.1.6.1.
(5)See Article 4.1.5.5.
Provenance
OBC 1997 · renumbered from 4.1.6.3. — Pro
Base · O. Reg. 350/06 · ext v0 → compare
O. Reg. 137/07, cl. 30 · ext ← current
In force 2007-04-02
OBC 2012 · continues as 4.1.5.3. — Pro