OBC 2006 › Division B
9.8.8.3.
Version 1 — in force 1 January 2010
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.8.8.3.
- Version
- v1
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.8.8.3.
- Version
- v1
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · renumbered from 9.8.8.2. — Pro
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 503/09, cl. 138 · ext ← current
In force 2010-01-01
OBC 2012 · continues as 9.8.8.3. — Pro
9.8.8.3. — Height of Guards
(1) Except as provided in Sentences (2) to (4), all guards shall be not less than 1 070 mm high.
(2) All guards within dwelling units shall be not less than 900 mm high.
(3) Exterior guards serving not more than one dwelling unit shall be not less than 900 mm high where the walking surface served by the guard is not more than 1 800 mm above the finished ground level.
(4) Guards for flights of steps, except in required exit stairs, shall be not less than 900 mm high.
(5) The height of guards for flights of steps shall be measured vertically from from the top of the guard to a line drawn through the leading edge of the treads served by the guard.
Editor's note
O. Reg. 503/09 cl. 138 amends Sentence (5) by striking out 'a line' and substituting 'from the top of the guard to a line'. Applied to the prior text ('... measured vertically from a line drawn through ...'), the amendment as filed produces a repeated 'from' ('... measured vertically from from the top of the guard to a line ...'). The e-Laws consolidation editorially renders this as a single 'from'; no part of the amendment directs that change. This map reflects the amendment as filed.
Provenance
OBC 1997 · renumbered from 9.8.8.2. — Pro
Base · O. Reg. 350/06 · ext v0 → compare
O. Reg. 503/09, cl. 138 · ext ← current
In force 2010-01-01
OBC 2012 · continues as 9.8.8.3. — Pro