CodeChronicle

OBC 2006 Division B

9.8.8.3.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 9.8.8.2. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

O. Reg. 503/09, cl. 138 · ext v1 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 138 · ext (not in force until 2010-01-01) v1 →

OBC 2012 · continues as 9.8.8.3. — Pro

9.8.8.3. — Height of Guards

(1) Except as provided in Sentences (2) to (4), all guards shall be not less than 1 070 mm high.

(2) All guards within dwelling units shall be not less than 900 mm high.

(3) Exterior guards serving not more than one dwelling unit shall be not less than 900 mm high where the walking surface served by the guard is not more than 1 800 mm above the finished ground level.

(4) Guards for flights of steps, except in required exit stairs, shall be not less than 900 mm high.

(5) The height of guards for flights of steps shall be measured vertically from a line drawn through the leading edge of the treads served by the guard.

Text · e-Laws consolidated snapshot