(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.8.6.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · renumbered from 9.8.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.8.6. — Pro
9.8.6. — Landings
Content not available for this version.
9.8.6.1. — Application
(1) This Subsection applies to landings, except landings for ramps in a barrier-free path of travel.
(2) Landings for ramps in a barrier-free path of travel shall conform to the requirements in Article 3.8.3.4.v1
(3) Finished floors, and ground surfaces with a slope not exceeding 1 in 100, at the top and bottom of stairs or ramps shall be considered as landings.
Text · e-Laws consolidated snapshot
9.8.6.2. — Required Landings
(1) Except as provided in Sentences (2) to (4) and Sentence 9.9.6.6.(2), a landing shall be provided,
(a) at the top and bottom of each flight of interior and exterior stairs, including stairs in garages,
(b) at the top and bottom of every ramp with a slope greater than 1 in 50, and
(c) where a doorway opens onto a stair or ramp.
(2) Where a door at the top of a stair in a dwelling unit swings away from the stair, no landing is required between the doorway and the stair.
(3) Except for an entrance from an attached garage, a landing may be omitted at the top of an exterior stair serving a secondary entrance to a single dwelling unit, provided,
(a) the stair does not contain more than 3 risers,
(b) except as provided in Clause (c), the door is a sliding door or swings away from the stair, and
(c) where a storm or screen door is provided, it may swing over the stair if it is equipped with hardware to hold it open.
(4) A landing may be omitted at the bottom of an exterior stair or ramp provided there is no obstruction, such as a gate or door, within the lesser of the width of the stair or ramp or,
(a) 900 mm for stairs or ramps serving a single dwelling unit, and
(b) 1100 mm for stairs or ramps not serving a single dwelling unit.
Text · e-Laws consolidated snapshot
9.8.6.3. — Dimensions of Landings
(1) Except as provided in Sentences (2) to (4), the width and length of landings shall comply with Table 9.8.6.3.
(2) Where stairs or ramps of different widths adjoin a single landing, the width of the landing shall be,
(a) not less than the greater required stair or ramp width where one or more of the stair or ramp widths do not exceed their respective required widths, or
(b) not less than the lesser actual stair or ramp width where all of the widths of the stairs or ramps exceed their respective required widths.
(3) Where a door swings toward a stair, the full arc of the swing shall be over the landing.
(4) Where a doorway or stairway opens onto the side of a ramp, the landing shall extend for a distance of not less than 300 mm on either side of the doorway or stairway, except on a side abutting an end wall.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 | Column 4 |
Application | Landing Configuration | Minimum Width, mm | Length, mm |
Stairs and ramps serving a single dwelling unit | In straight-run stair or ramp, or landing turning through less than 30°, within a dwelling unit | Width of stair or ramp | Not less than 860 |
In straight-run exterior stair or ramp, or exterior landing turning through less than 30° | Width of stair or ramp | Not less than 900 | |
Landing turning through an angle of 30° or more, but less than 90° | Width of stair or ramp measured at right angle to path of travel | (a) Not less than 230 measured at the inside edge of the landing, and (b) Not less than 370 measured 230 mm from the inside edge of landing or handrail | |
Landing turning through not less than 90° | Width of stair or ramp measured at right angle to path of travel | Not less than width of landing | |
Stairs and ramps serving other than single dwelling units | In straight-run stair or ramp, or landing turning through less than 30° | Width of stair or ramp | Lesser of required width of stair or ramp, or 1 100 |
Landing turning through 30° or more | Width of stair or ramp measured at right angle to path of travel | Not less than width of stair or landing |
9.8.6.4. — Height over Landings
(1) The clear height over landings shall be not less than,
(a) 1 950 mm for landings within dwelling units, and
(b) 2 050 mm for landings not within dwelling units.