CodeChronicle

OBC 2006 Division B

9.8.5.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 9.8.6. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.8.5. — Pro

9.8.5. — Ramps

Content not available for this version.

9.8.5.1. — Application

(1) This Subsection applies to pedestrian ramps except ramps in a barrier-free path of travel.

(2) Ramps in a barrier-free path of travel shall conform to the requirements in Article 3.8.3.4.v1

Text · e-Laws consolidated snapshot

9.8.5.2. — Ramp Width

(1) Except for required exit ramps, public ramps shall have a width of not less than 900 mm.

(2) Ramps within dwelling units, and exterior ramps serving a single dwelling unit except required exit ramps, shall have a width of not less than 860 mm.

Text · e-Laws consolidated snapshot

9.8.5.3. — Height over Ramps

(1) The clear height over ramps shall be not less than,

(a) 1 950 mm for ramps within dwelling units, and

(b) 2 050 mm for ramps not within dwelling units.

Text · e-Laws consolidated snapshot

9.8.5.4. — Slope

(1) The slope of ramps shall be not more than,

(a) 1 in 10 for exterior ramps,

(b) 1 in 10 for interior ramps serving residential occupancies,

(c) 1 in 6 for mercantile or industrial occupancies, and

(d) 1 in 8 for all other occupancies.

Text · e-Laws consolidated snapshot

9.8.5.5. — Maximum Rise

(1) Where the slope of the ramp is greater than 1 in 12, the maximum rise between floors or landings shall be 1 500 mm.

Text · e-Laws consolidated snapshot