CodeChronicle

OBC 2006 Division B

9.8.2.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.8.2. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.8.2. — Pro

9.8.2. — Stair Dimensions

Content not available for this version.

9.8.2.1. — Stair Width

(1) Required exit stairs and public stairs shall have a width, measured between wall faces or guards, of not less than 900 mm.

(2) At least 1 stair between each floor level within a dwelling unit, and exterior stairs serving a single dwelling unit except required exit stairs, shall have a width of not less than 860 mm.

Text · e-Laws consolidated snapshot

9.8.2.2. — Height over Stairs

(1) The clear height over stairs measured vertically from a line drawn through the leading edges of the treads, shall be not less than,

(a) 1 950 mm for stairs within dwelling units, and

(b) 2 050 mm for stairs not within dwelling units.

Text · e-Laws consolidated snapshot