9.7.5.4. — Windows above the Second Storey

(1) Windows in public areas that extend to less than 1 000 mm from the floor and are located above the second storey in buildings of residential occupancy shall be,

(a) protected by guards in accordance with Subsection 9.8.8., or

(b) non-openable and designed to withstand the lateral design loads for guards as provided in Articles 4.1.5.15.v1 or 9.8.8.2.v1

Editor's note

As filed in O. Reg. 350/06, Clause (1)(b) cites 'Articles 4.1.5.15. or 9.8.8.2.' using the plural 'Articles'; the consolidated e-Laws text renders the reference word in the singular ('Article'). No amending regulation makes this change; the as-filed wording is retained here.