CodeChronicle

OBC 2006 Division B

9.6.8.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.6.8. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · merged into 9.7.5. — Pro

9.6.8. — Resistance to Forced Entry

Content not available for this version.

9.6.8.1. — Application

(1) Except as permitted in Sentence (2), this Subsection applies to,

(a) swinging entrance doors to dwelling units,

(b) swinging doors between dwelling units and attached garages or other ancillary spaces, and

(c) swinging doors that provide access directly or indirectly from a storage garage to a dwelling unit.

(2) Sentence (1) does not apply to exterior doors to garages and to other ancillary spaces.

Text · e-Laws consolidated snapshot

9.6.8.2. — Wood Doors

(1) Except as permitted in Article 9.6.8.10., wood doors as described in Sentence 9.6.8.1.(1) shall,

(a) be solid core or stile and rail type,

(b) be not less than 45 mm thick, and

(c) if of the stile and rail panel type, have a panel thickness of not less than 19 mm, with a total panel area not more than half of the door area.

Text · e-Laws consolidated snapshot

9.6.8.3. — Deadbolt Lock

(1) Except as permitted in Article 9.6.8.10., doors described in Sentence 9.6.8.1.(1) shall be provided with a deadbolt lock with a cylinder having no fewer than 5 pins and a bolt throw not less than 25 mm, protected with a solid or hardened free-turning ring or bevelled cylinder housing.

Text · e-Laws consolidated snapshot

9.6.8.4. — Double Doors

(1) Except as permitted in Article 9.6.8.10., an inactive leaf in double doors used in locations specified in Sentence 9.6.8.1.(1) shall be provided with heavy duty bolts top and bottom having an engagement of not less than 15 mm.

Text · e-Laws consolidated snapshot

9.6.8.5. — Fastening of Hinges

(1) Except as permitted in Article 9.6.8.10., hinges for doors in Sentence 9.6.8.1.(1) shall be fastened to wood doors with wood screws not less than 25 mm long and to wood frames with wood screws such that at least two screws per hinge penetrate not less than 30 mm into solid wood.

(2) Except as permitted in Article 9.6.8.10., hinges for doors in Sentence 9.6.8.1.(1) shall be fastened to metal doors and metal frames with machine screws not smaller than No. 8 and not less than 10 mm long.

Text · e-Laws consolidated snapshot

9.6.8.6. — Fastening of Strikeplates

(1) Except as permitted in Article 9.6.8.10., strikeplates for deadbolts described in Sentence 9.6.8.3.(1) shall be fastened to wood frames with wood screws that penetrate not less than 30 mm into solid wood.

(2) Except as permitted in Article 9.6.8.10., strikeplates for deadbolts in Sentence 9.6.8.3.(1) shall be fastened to metal frames with machine screws not smaller than No. 8 and not less than 10 mm long.

Text · e-Laws consolidated snapshot

9.6.8.7. — Outward Swinging Doors

(1) Except for storm doors or screen doors, doors described in Sentence 9.6.8.1.(1) that swing outward shall be provided with hinges or pins so that the doors cannot be removed when they are in the closed position.

Text · e-Laws consolidated snapshot

9.6.8.8. — Door Viewer

(1) Main entrance doors to dwelling units shall be provided with,

(a) a door viewer or transparent glazing in the door, or

(b) a sidelight.

Text · e-Laws consolidated snapshot

9.6.8.9. — Solid Blocking

(1) Solid blocking shall be provided on both sides at the lock height between the jambs for doors described in Sentence 9.6.8.1.(1) and the structural framing so that the jambs will resist spreading by force.

Text · e-Laws consolidated snapshot

9.6.8.10. — Alternate Test Procedure

(1) Doors, frames and hardware that conform to a security level of at least Grade 10 as described in the Annex to ASTM F476, “Security of Swinging Door Assemblies”, are not required to conform to Articles 9.6.8.2. to 9.6.8.6.