9.6.6. — Glass

Content not available for this version.

9.6.6.1. — Maximum Area of Glass

(1) The maximum area of individual panes of glass for doors shall conform to Table 9.6.6.1.

Editor's note

As filed in O. Reg. 350/06, the headings for Column 5 and Column 7 of Table 9.6.6.1. appear as '5 Column' and '7 Column' (number before the word), the 'Notes to Table 9.6.6.1.:' headnote is bold, and the footnote reference '(1)' is shown inline. The consolidated e-Laws text normalizes the headings to 'Column 5' and 'Column 7', sets the headnote in regular weight, and presents the footnote reference as a superscript. No amending regulation makes any of these changes; the as-filed wording and presentation are retained here.

Text · e-Laws consolidated snapshot

Table 9.6.6.1. Maximum Glass Area for Doors Forming Part of Sentence 9.6.6.1.(1)

Column 1

Column 2

Column 3

Column 4

5 Column

Column 6

7 Column

Column 8

Maximum Glass Area, m2

Type of Glass

Glass Thickness, mm

Annealed

Annealed Multiple-Glazed Factory-Sealed Units

Laminated

Wired

Heat Strengthened

Fully Tempered

Fully Tempered Multiple-Glazed Factory-Sealed Units

3

0.50

0.70

(1)

(1)

1.00

1.00

2.00

4

1.00

1.50

(1)

(1)

1.50

4.00

4.00

5

1.50

1.50

(1)

(1)

1.50

No Limit

No Limit

6

1.50

1.50

1.20

1.00

1.50

No Limit

No Limit

Notes to Table 9.6.6.1.:

(1)Not generally available.

9.6.6.2. — Glass in Doors and Sidelights

(1) Glass in doors and sidelights for doors shall conform to Sentence 9.7.3.1.(1).

(2) Glass in sidelights greater than 500 mm wide that could be mistaken for doors, glass in storm doors and glass in sliding doors within or at every entrance to a dwelling unit and in public areas shall be,

(a) safety glass of the tempered or laminated type conforming to CAN/CGSB-12.1-M, “Tempered or Laminated Safety Glass”, or

(b) wired glass conforming to CAN/CGSB-12.11-M, “Wired Safety Glass”.

(3) Except as provided in Article 9.7.5.2., glass in entrance doors to dwelling units and in public areas other than the entrance door described in Sentence (2), shall be safety glass or wired glass of the type described in Sentence (2) where the glass area exceeds 0.5 m2 and extends to less than 900 mm from the bottom of the door.

Text · e-Laws consolidated snapshot

9.6.6.3. — Mirrored Glass Doors

(1) Mirrored glass doors are permitted to be used only at the entrance to clothes closets and shall conform to the requirements of CAN/CGSB-82.6-M, “Doors, Mirrored Glass, Sliding or Folding Wardrobe”.

(2) Mirrored glass doors reinforced with a film backing shall meet the impact resistance requirements specified in CAN/CGSB-12.5-M, “Mirrors, Silvered”.

Text · e-Laws consolidated snapshot

9.6.6.4. — Visibility of Glass or Transparent Doors

(1) Except as provided in Article 9.7.5.2., every glass or transparent door accessible to the public shall be equipped with hardware, bars or other permanent fixtures designed so that the existence and position of such door will be readily apparent.

Text · e-Laws consolidated snapshot

9.6.6.5. — Glass for Shower or Bathtub Enclosures

(1) Glass other than safety glass shall not be used for a shower or bathtub enclosure.