CodeChronicle

OBC 2006 Division B

9.33.4.3.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.33.4.3. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

O. Reg. 503/09, cl. 193(2) · ext v1 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 193(2) · ext (not in force until 2010-01-01) v1 →

OBC 2012 · continues as 9.33.4.3. — Pro

9.33.4.3. — Installation and Conformance to Standards

Comparing versions

Changed text stands out · unchanged is dimmed

v0 base

Earlier · viewing · 2006-12-31

(1) The carbon monoxide detector required by Article 9.33.4.2. shall,

(a) be permanently connected to an electrical circuit and shall have no disconnect switch between the overcurrent device and the carbon monoxide detector,

(b) be wired so that its activation will activate all carbon monoxide detectors within the suite, where located within a suite of residential occupancy,

(c) be equipped with an alarm that is audible within bedrooms when the intervening doors are closed, where located adjacent to a sleeping area, and

(d) conform to,

(i) CAN/CSA-6.19, “Residential Carbon Monoxide Alarming Devices”, or

(ii) UL 2034, “Single and Multiple Station Carbon Monoxide Alarms”.

v1 O. Reg. 503/09

Later · 2010-01-01

(1) The carbon monoxide detector required by Article 9.33.4.2. shall,

(a) except as permitted in Sentence (2), be permanently connected to an electrical circuit and shall have no disconnect switch between the overcurrent device and the carbon monoxide detector,

(b) be wired so that its activation will activate all carbon monoxide detectors within the suite, where located within a suite of residential occupancy,

(c) be equipped with an alarm that is audible within bedrooms when the intervening doors are closed, where located adjacent to a sleeping area, and

(d) conform to,

(i) CAN/CSA-6.19, “Residential Carbon Monoxide Alarming Devices”, or

(ii) UL 2034, “Single and Multiple Station Carbon Monoxide Alarms”.

(2) Where the building is not supplied with electrical power, carbon monoxide detectors are permitted to be battery operated.