CodeChronicle

OBC 2006 Division B

9.23.16.6.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.23.16.6. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

O. Reg. 503/09, cl. 178 · ext v1 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 178 · ext (not in force until 2010-01-01) v1 →

OBC 2012 · continues as 9.23.16.6. — Pro

9.23.16.6. — Mansard Style Roofs

Comparing versions

Changed text stands out · unchanged is dimmed

v0 base

Earlier · viewing · 2006-12-31

(1) Where the bottom portions of mansard style roofs are vented, the vertical framing members behind the sloping portions shall be considered on the same basis as exterior wall studs and shall conform to the appropriate requirements in Subsection 9.23.17.

v1 O. Reg. 503/09

Later · 2010-01-01

(1) Where the bottom portions of mansard style roofs are vented, the vertical framing members behind the sloping portions shall be considered on the same basis as exterior wall studs and shall conform to the appropriate requirements in Articles 9.27.3.2. to 9.27.3.6.