OBC 2006 › Division B
9.23.16.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.23.16.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.23.16.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.23.16. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.23.16. — Pro
9.23.16. — Wall Sheathing
Content not available for this version.
9.23.16.1. — Required Sheathing
(1) Exterior walls and gable ends shall be sheathed when the exterior cladding requires intermediate fastening between supports or if the exterior cladding requires solid backing.
Text · e-Laws consolidated snapshot
9.23.16.2. — Thickness, Rating and Material Standards
(1) Where wall sheathing is required, it shall conform to Table 9.23.16.2.A. or Table 9.23.16.2.B.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 | Column 4 |
Type of Sheathing | Minimum Thickness, mm(1) | Material Standards | |
With Supports 400 mm o.c. | With Supports 600 mm o.c. | ||
Fibreboard (insulating) | 9.5 | 11.1 | CAN/ULC-S706 |
Gypsum Sheathing | 9.5 | 12.7 | CAN/CSA-A82.27-M |
ASTM C79 / C79M | |||
ASTM C1177 / C1177M | |||
ASTM C1396 / C1396M | |||
Lumber | 17.0 | 17.0 | See Table 9.3.2.1.v1 |
Mineral Fibre, Rigid Board, Type 2 | 25 | 25 | CAN/ULC-S702 |
OSB, O-2 Grade | 6.0 | 7.5 | CSA O437.0 |
OSB, O-1 Grade, and Waferboard, R-1 Grade | 6.35 | 7.9 | CSA O437.0 |
Phenolic, faced | 25 | 25 | CAN/CGSB-51.25-M |
Plywood (exterior type) | 6 | 7.5 | CSA O121-M |
CSA O151 | |||
CSA O153-M | |||
Polystyrene, Types 1 and 2 | 38 | 38 | CAN/ULC-S701 |
Polystyrene, Types 3 and 4 | 25 | 25 | CAN/ULC-S701 |
Polyurethane and Polyisocycanurate Type 1, faced | 38 | 38 | CAN/ULC-S704 |
Polyurethane and Polyisocycanurate Types 2 and 3, faced | 25 | 25 | CAN/ULC-S704 |
Notes to Table 9.23.16.2.A.:
(1)See also Sentences 9.27.5.1.(2) to (4).
Column 1 | Column 2 |
Maximum Spacing of Supports, mm | Panel Mark |
400 | W16 |
500 | W20 |
600 | W24 |
9.23.16.3. — Attachment of Cladding to Sheathing
(1) Gypsum sheathing, rigid insulation and fibreboard shall not be used for the attachment of siding materials.
(2) Nails used in attaching the materials listed in Sentence (1) shall be not less than 3.2 mm diam with a minimum head diameter of 11 mm.
Text · e-Laws consolidated snapshot
9.23.16.4. — Lumber Sheathing
(1) Lumber wall sheathing shall be applied so that all ends are supported.
(2) Where lumber wall sheathing is required to provide bracing according to Article 9.23.10.2., it shall be applied with end joints staggered.
Text · e-Laws consolidated snapshot
9.23.16.5. — Joints in Panel-Type Sheathing
(1) A gap of not less than 2 mm shall be left between sheets of plywood, OSB, waferboard or fibreboard.
Text · e-Laws consolidated snapshot
9.23.16.6. — Mansard Style Roofs
(1) Where the bottom portions of mansard style roofs are vented, the vertical framing members behind the sloping portions shall be considered on the same basis as exterior wall studs and shall conform to the appropriate requirements in Subsection 9.23.17.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 9.23.16. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.23.16. — Pro