CodeChronicle

OBC 2006 Division B

9.20.17.3.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

New in this edition — no OBC 1997 predecessor

Base · O. Reg. 350/06 · ext← current

Original — base regulation

O. Reg. 137/07, cl. 58 · ext v1 →

In force 2007-04-02

O. Reg. 503/09, cl. 169 · ext v2 →

In force 2010-01-01

Next: O. Reg. 137/07, cl. 58 · ext (not in force until 2007-04-02) v1 →

OBC 2012 · continues as 9.20.17.3. — Pro

9.20.17.3. — Openings in Flat Non-Loadbearing Insulating Concrete Form Walls

(1) No openings shall occur within 1 200 mm of interior and exterior corners of exterior non-loadbearing flat insulating concrete form walls.

(2) Portions of walls over openings in non-loadbearing flat insulating concrete form walls shall have a minimum depth of concrete of not less than 200 mm over the width of the opening.

(3) Openings more than 600 mm but not more than 3 000 mm in width in non-loadbearing flat insulating concrete form walls shall be reinforced at the top and bottom with one 10M bar.

(4) Openings more than 3 000 mm in width in non-loadbearing flat insulating concrete form walls shall be reinforced on all four sides with two 10M bar.

(5) Reinforcing bars described in Sentences (3) and (4) shall extend not less than 600 mm beyond the edges of the opening.

(6) The cumulative width of openings in non-loadbearing flat insulating concrete form walls shall be not more than 70% of the length of any wall.

Text · e-Laws consolidated snapshot